Painel solar TOPCon de 520 W com 132 células. Voc 47 V · Isc 13,4 A · TcVoc -0,25%/°C.
Escolha o painel que precisa de substituir
14 painéis encontrados · 4325 painéis excluídos
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.35 V | 2,9% |
| Vmpp | 40.1 V | 40.61 V | 1,3% |
| Isc | 13.4 A | 13.88 A | 3,6% |
| Impp | 13 A | 13.3 A | 2,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47 V | 0,0% |
| Vmpp | 40.1 V | 38.9 V | 3,0% |
| Isc | 13.4 A | 14.35 A | 7,1% |
| Impp | 13 A | 13.62 A | 4,8% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
520 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.27 V | 2,7% |
| Vmpp | 40.1 V | 39.91 V | 0,5% |
| Isc | 13.4 A | 13.84 A | 3,3% |
| Impp | 13 A | 13.03 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.81 V | 1,7% |
| Vmpp | 40.1 V | 40.24 V | 0,3% |
| Isc | 13.4 A | 14.22 A | 6,1% |
| Impp | 13 A | 13.17 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.68 V | 1,4% |
| Vmpp | 40.1 V | 39.79 V | 0,8% |
| Isc | 13.4 A | 14.34 A | 7,0% |
| Impp | 13 A | 13.57 A | 4,4% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 46.6 V | 0,9% |
| Vmpp | 40.1 V | 38.7 V | 3,5% |
| Isc | 13.4 A | 14.2 A | 6,0% |
| Impp | 13 A | 13.44 A | 3,4% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.4 V | 0,9% |
| Vmpp | 40.1 V | 39.1 V | 2,5% |
| Isc | 13.4 A | 14.49 A | 8,1% |
| Impp | 13 A | 13.81 A | 6,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.04 V | 2,2% |
| Vmpp | 40.1 V | 40.44 V | 0,8% |
| Isc | 13.4 A | 14.29 A | 6,6% |
| Impp | 13 A | 13.23 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.27 V | 2,7% |
| Vmpp | 40.1 V | 40.64 V | 1,3% |
| Isc | 13.4 A | 14.35 A | 7,1% |
| Impp | 13 A | 13.29 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 46.2 V | 1,7% |
| Vmpp | 40.1 V | 38.5 V | 4,0% |
| Isc | 13.4 A | 14.05 A | 4,9% |
| Impp | 13 A | 13.25 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 45.9 V | 2,3% |
| Vmpp | 40.1 V | 38.3 V | 4,5% |
| Isc | 13.4 A | 13.9 A | 3,7% |
| Impp | 13 A | 13.19 A | 1,5% |
| TcVoc | -0.25 %/°C | -0.29 %/°C | ±0,040 %/°C |
| TcPmax | -0.3 %/°C | -0.35 %/°C | ±0,050 %/°C |
505 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 45.9 V | 2,3% |
| Vmpp | 40.1 V | 38.3 V | 4,5% |
| Isc | 13.4 A | 13.9 A | 3,7% |
| Impp | 13 A | 13.19 A | 1,5% |
| TcVoc | -0.25 %/°C | -0.29 %/°C | ±0,040 %/°C |
| TcPmax | -0.3 %/°C | -0.35 %/°C | ±0,050 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
47 V
Vmpp
40,1 V
Isc
13,4 A
Impp
13 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
520 W
Cells
132
Comprimento
2094 mm
Largura
1134 mm
Espessura
30 mm
Peso
24,6 kg
O EcoFlow EF-SG-520 é um painel solar de 520 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
As especificações mais críticas são: número de células (exatamente 132), Voc próximo a 47 V (±5%) e coeficiente de temperatura TcVoc próximo a -0,25%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o EcoFlow EF-SG-520 original.