Painel solar TOPCon de 600 W com 144 células. Voc 52 V · Isc 14,44 A · TcVoc -0,24%/°C.
Escolha o painel que precisa de substituir
133 painéis encontrados · 4206 painéis excluídos
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.94 V | 0,1% |
| Vmpp | 43.4 V | 43.13 V | 0,6% |
| Isc | 14.44 A | 14.64 A | 1,4% |
| Impp | 13.83 A | 13.91 A | 0,6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.07 V | 0,1% |
| Vmpp | 43.4 V | 43.24 V | 0,4% |
| Isc | 14.44 A | 14.72 A | 1,9% |
| Impp | 13.83 A | 13.99 A | 1,2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.02 V | 0,0% |
| Vmpp | 43.4 V | 43.41 V | 0,0% |
| Isc | 14.44 A | 14.36 A | 0,6% |
| Impp | 13.83 A | 13.59 A | 1,7% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.81 V | 0,4% |
| Vmpp | 43.4 V | 43.02 V | 0,9% |
| Isc | 14.44 A | 14.56 A | 0,8% |
| Impp | 13.83 A | 13.83 A | 0,0% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.95 V | 0,1% |
| Vmpp | 43.4 V | 43.67 V | 0,6% |
| Isc | 14.44 A | 14.18 A | 1,8% |
| Impp | 13.83 A | 13.51 A | 2,3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.6 V | 0,8% |
| Vmpp | 43.4 V | 43.4 V | 0,0% |
| Isc | 14.44 A | 14.34 A | 0,7% |
| Impp | 13.83 A | 13.59 A | 1,7% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.11 V | 0,2% |
| Vmpp | 43.4 V | 43.04 V | 0,8% |
| Isc | 14.44 A | 14.34 A | 0,7% |
| Impp | 13.83 A | 13.48 A | 2,5% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.95 V | 0,1% |
| Vmpp | 43.4 V | 43.76 V | 0,8% |
| Isc | 14.44 A | 14.62 A | 1,2% |
| Impp | 13.83 A | 13.83 A | 0,0% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
52 V
Vmpp
43,4 V
Isc
14,44 A
Impp
13,83 A
TcVoc
-0,24 %/°C
TcPmax
-0,3 %/°C
Pmax
600 W
Cells
144
Comprimento
2278 mm
Largura
1134 mm
Espessura
30 mm
Peso
27,7 kg
O Tensite EM600-PH 30mm é um painel solar de 600 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
As especificações mais críticas são: número de células (exatamente 144), Voc próximo a 52 V (±5%) e coeficiente de temperatura TcVoc próximo a -0,24%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Tensite EM600-PH 30mm original.