500 W ABC Solarmodul mit 108 Zellen. Voc 41,3 V · Isc 14,96 A · TcVoc -0,22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
90 Module gefunden · 3620 Module ausgeschlossen
480 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.3 V | 0,0% |
| Vmpp | 34.9 V | 34.86 V | 0,1% |
| Isc | 14.96 A | 14.38 A | 3,9% |
| Impp | 14.33 A | 13.78 A | 3,8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
485 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.36 V | 0,1% |
| Vmpp | 34.9 V | 34.92 V | 0,1% |
| Isc | 14.96 A | 14.41 A | 3,7% |
| Impp | 14.33 A | 13.9 A | 3,0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
510 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.11 V | 0,5% |
| Vmpp | 34.9 V | 34.57 V | 0,9% |
| Isc | 14.96 A | 15.52 A | 3,7% |
| Impp | 14.33 A | 14.76 A | 3,0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
480 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 40.9 V | 1,0% |
| Vmpp | 34.9 V | 34.5 V | 1,1% |
| Isc | 14.96 A | 14.8 A | 1,1% |
| Impp | 14.33 A | 13.92 A | 2,9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
505 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 40.96 V | 0,8% |
| Vmpp | 34.9 V | 34.47 V | 1,2% |
| Isc | 14.96 A | 15.45 A | 3,3% |
| Impp | 14.33 A | 14.66 A | 2,3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
505 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 40.96 V | 0,8% |
| Vmpp | 34.9 V | 34.47 V | 1,2% |
| Isc | 14.96 A | 15.45 A | 3,3% |
| Impp | 14.33 A | 14.66 A | 2,3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
490 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.25 V | 0,1% |
| Vmpp | 34.9 V | 34.07 V | 2,4% |
| Isc | 14.96 A | 15.04 A | 0,5% |
| Impp | 14.33 A | 14.38 A | 0,3% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0,010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
495 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.35 V | 0,1% |
| Vmpp | 34.9 V | 34.17 V | 2,1% |
| Isc | 14.96 A | 15.15 A | 1,3% |
| Impp | 14.33 A | 14.49 A | 1,1% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0,010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
500 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.35 V | 0,1% |
| Vmpp | 34.9 V | 34.17 V | 2,1% |
| Isc | 14.96 A | 15.3 A | 2,3% |
| Impp | 14.33 A | 14.63 A | 2,1% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0,010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
495 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.25 V | 0,1% |
| Vmpp | 34.9 V | 34.07 V | 2,4% |
| Isc | 14.96 A | 15.19 A | 1,5% |
| Impp | 14.33 A | 14.53 A | 1,4% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0,010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
500 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 41.45 V | 0,4% |
| Vmpp | 34.9 V | 34.27 V | 1,8% |
| Isc | 14.96 A | 15.26 A | 2,0% |
| Impp | 14.33 A | 14.59 A | 1,8% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0,010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
500 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.3 V | 40.81 V | 1,2% |
| Vmpp | 34.9 V | 34.37 V | 1,5% |
| Isc | 14.96 A | 15.39 A | 2,9% |
| Impp | 14.33 A | 14.55 A | 1,5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
41,3 V
Vmpp
34,9 V
Isc
14,96 A
Impp
14,33 A
TcVoc
-0,22 %/°C
TcPmax
-0,26 %/°C
Pmax
500 W
Cells
108
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24,2 kg
Das Aiko Solar AIKO-A500-MCE54Db ist ein 500 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 41,3 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Aiko Solar AIKO-A500-MCE54Db übereinstimmen.