585 W TOPCon Solarmodul mit 144 Zellen. Voc 52,4 V · Isc 14 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
125 Module gefunden · 4214 Module ausgeschlossen
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.31 V | 0,2% |
| Vmpp | 43.3 V | 43.35 V | 0,1% |
| Isc | 14 A | 14.01 A | 0,1% |
| Impp | 13.52 A | 13.38 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.42 V | 0,0% |
| Vmpp | 43.3 V | 43.3 V | 0,0% |
| Isc | 14 A | 14.38 A | 2,7% |
| Impp | 13.52 A | 13.52 A | 0,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.47 V | 0,1% |
| Vmpp | 43.3 V | 43.53 V | 0,5% |
| Isc | 14 A | 14.01 A | 0,1% |
| Impp | 13.52 A | 13.44 A | 0,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.4 V | 0,0% |
| Vmpp | 43.3 V | 43.7 V | 0,9% |
| Isc | 14 A | 14.22 A | 1,6% |
| Impp | 13.52 A | 13.39 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.2 V | 0,4% |
| Vmpp | 43.3 V | 43.1 V | 0,5% |
| Isc | 14 A | 13.93 A | 0,5% |
| Impp | 13.52 A | 13.46 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.36 V | 0,1% |
| Vmpp | 43.3 V | 43.43 V | 0,3% |
| Isc | 14 A | 13.61 A | 2,8% |
| Impp | 13.52 A | 13.36 A | 1,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.15 V | 0,5% |
| Vmpp | 43.3 V | 43.17 V | 0,3% |
| Isc | 14 A | 13.95 A | 0,4% |
| Impp | 13.52 A | 13.32 A | 1,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.2 V | 0,4% |
| Vmpp | 43.3 V | 43.5 V | 0,5% |
| Isc | 14 A | 14.15 A | 1,1% |
| Impp | 13.52 A | 13.34 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.48 V | 0,2% |
| Vmpp | 43.3 V | 43.61 V | 0,7% |
| Isc | 14 A | 13.67 A | 2,4% |
| Impp | 13.52 A | 13.42 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.63 V | 0,4% |
| Vmpp | 43.3 V | 43.71 V | 0,9% |
| Isc | 14 A | 14.13 A | 0,9% |
| Impp | 13.52 A | 13.5 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52.63 V | 0,4% |
| Vmpp | 43.3 V | 43.71 V | 0,9% |
| Isc | 14 A | 14.13 A | 0,9% |
| Impp | 13.52 A | 13.5 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.4 V | 52 V | 0,8% |
| Vmpp | 43.3 V | 43.3 V | 0,0% |
| Isc | 14 A | 14.08 A | 0,6% |
| Impp | 13.52 A | 13.28 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
52,4 V
Vmpp
43,3 V
Isc
14 A
Impp
13,52 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
585 W
Cells
144
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
27,6 kg
Das Canadian Solar CS6W-585T ist ein 585 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 52,4 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Canadian Solar CS6W-585T übereinstimmen.