520 W TOPCon Solarmodul mit 132 Zellen. Voc 47 V · Isc 13,4 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
14 Module gefunden · 4325 Module ausgeschlossen
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.35 V | 2,9% |
| Vmpp | 40.1 V | 40.61 V | 1,3% |
| Isc | 13.4 A | 13.88 A | 3,6% |
| Impp | 13 A | 13.3 A | 2,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47 V | 0,0% |
| Vmpp | 40.1 V | 38.9 V | 3,0% |
| Isc | 13.4 A | 14.35 A | 7,1% |
| Impp | 13 A | 13.62 A | 4,8% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
520 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.27 V | 2,7% |
| Vmpp | 40.1 V | 39.91 V | 0,5% |
| Isc | 13.4 A | 13.84 A | 3,3% |
| Impp | 13 A | 13.03 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.81 V | 1,7% |
| Vmpp | 40.1 V | 40.24 V | 0,3% |
| Isc | 13.4 A | 14.22 A | 6,1% |
| Impp | 13 A | 13.17 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.68 V | 1,4% |
| Vmpp | 40.1 V | 39.79 V | 0,8% |
| Isc | 13.4 A | 14.34 A | 7,0% |
| Impp | 13 A | 13.57 A | 4,4% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 46.6 V | 0,9% |
| Vmpp | 40.1 V | 38.7 V | 3,5% |
| Isc | 13.4 A | 14.2 A | 6,0% |
| Impp | 13 A | 13.44 A | 3,4% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 47.4 V | 0,9% |
| Vmpp | 40.1 V | 39.1 V | 2,5% |
| Isc | 13.4 A | 14.49 A | 8,1% |
| Impp | 13 A | 13.81 A | 6,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.04 V | 2,2% |
| Vmpp | 40.1 V | 40.44 V | 0,8% |
| Isc | 13.4 A | 14.29 A | 6,6% |
| Impp | 13 A | 13.23 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 48.27 V | 2,7% |
| Vmpp | 40.1 V | 40.64 V | 1,3% |
| Isc | 13.4 A | 14.35 A | 7,1% |
| Impp | 13 A | 13.29 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 46.2 V | 1,7% |
| Vmpp | 40.1 V | 38.5 V | 4,0% |
| Isc | 13.4 A | 14.05 A | 4,9% |
| Impp | 13 A | 13.25 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 45.9 V | 2,3% |
| Vmpp | 40.1 V | 38.3 V | 4,5% |
| Isc | 13.4 A | 13.9 A | 3,7% |
| Impp | 13 A | 13.19 A | 1,5% |
| TcVoc | -0.25 %/°C | -0.29 %/°C | ±0,040 %/°C |
| TcPmax | -0.3 %/°C | -0.35 %/°C | ±0,050 %/°C |
505 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47 V | 45.9 V | 2,3% |
| Vmpp | 40.1 V | 38.3 V | 4,5% |
| Isc | 13.4 A | 13.9 A | 3,7% |
| Impp | 13 A | 13.19 A | 1,5% |
| TcVoc | -0.25 %/°C | -0.29 %/°C | ±0,040 %/°C |
| TcPmax | -0.3 %/°C | -0.35 %/°C | ±0,050 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
47 V
Vmpp
40,1 V
Isc
13,4 A
Impp
13 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
520 W
Cells
132
Länge
2094 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24,6 kg
Das EcoFlow EF-SG-520 ist ein 520 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 47 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original EcoFlow EF-SG-520 übereinstimmen.