400 W PERC Solarmodul mit 108 Zellen. Voc 36,78 V · Isc 13,52 A · TcVoc -0,28%/°C.
Wählen Sie das Modul, das ersetzt werden soll
74 Module gefunden · 4265 Module ausgeschlossen
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.78 V | 0,0% |
| Vmpp | 31.01 V | 31.01 V | 0,0% |
| Isc | 13.52 A | 13.52 A | 0,0% |
| Impp | 12.9 A | 12.9 A | 0,0% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.77 V | 0,0% |
| Vmpp | 31.01 V | 30.89 V | 0,4% |
| Isc | 13.52 A | 13.52 A | 0,0% |
| Impp | 12.9 A | 12.8 A | 0,8% |
| TcVoc | -0.28 %/°C | -0.285 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.63 V | 0,4% |
| Vmpp | 31.01 V | 30.86 V | 0,5% |
| Isc | 13.52 A | 13.42 A | 0,7% |
| Impp | 12.9 A | 12.8 A | 0,8% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.93 V | 0,4% |
| Vmpp | 31.01 V | 31.16 V | 0,5% |
| Isc | 13.52 A | 13.61 A | 0,7% |
| Impp | 12.9 A | 13 A | 0,8% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.9 V | 0,3% |
| Vmpp | 31.01 V | 30.7 V | 1,0% |
| Isc | 13.52 A | 13.63 A | 0,8% |
| Impp | 12.9 A | 12.87 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 37.01 V | 0,6% |
| Vmpp | 31.01 V | 31.09 V | 0,3% |
| Isc | 13.52 A | 13.6 A | 0,6% |
| Impp | 12.9 A | 12.88 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.285 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.9 V | 0,3% |
| Vmpp | 31.01 V | 30.7 V | 1,0% |
| Isc | 13.52 A | 13.63 A | 0,8% |
| Impp | 12.9 A | 12.87 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.9 V | 0,3% |
| Vmpp | 31.01 V | 30.7 V | 1,0% |
| Isc | 13.52 A | 13.63 A | 0,8% |
| Impp | 12.9 A | 12.87 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
390 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.48 V | 0,8% |
| Vmpp | 31.01 V | 30.71 V | 1,0% |
| Isc | 13.52 A | 13.33 A | 1,4% |
| Impp | 12.9 A | 12.7 A | 1,6% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 36.75 V | 0,1% |
| Vmpp | 31.01 V | 30.75 V | 0,8% |
| Isc | 13.52 A | 13.76 A | 1,8% |
| Impp | 12.9 A | 13.01 A | 0,9% |
| TcVoc | -0.28 %/°C | -0.265 %/°C | ±0,015 %/°C |
| TcPmax | -0.35 %/°C | -0.34 %/°C | ±0,010 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 37.08 V | 0,8% |
| Vmpp | 31.01 V | 31.14 V | 0,4% |
| Isc | 13.52 A | 13.57 A | 0,4% |
| Impp | 12.9 A | 12.85 A | 0,4% |
| TcVoc | -0.28 %/°C | -0.285 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.78 V | 37.08 V | 0,8% |
| Vmpp | 31.01 V | 31.14 V | 0,4% |
| Isc | 13.52 A | 13.57 A | 0,4% |
| Impp | 12.9 A | 12.85 A | 0,4% |
| TcVoc | -0.28 %/°C | -0.285 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
36,78 V
Vmpp
31,01 V
Isc
13,52 A
Impp
12,9 A
TcVoc
-0,28 %/°C
TcPmax
-0,35 %/°C
Pmax
400 W
Cells
108
Länge
1734 mm
Breite
1146 mm
Rahmentiefe
30 mm
Gewicht
25,3 kg
Das GCL-M10/54GDF-B ist ein 400 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 36,78 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,28%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original GCL-M10/54GDF-B übereinstimmen.