550 W PERC Solarmodul mit 144 Zellen. Voc 50,22 V · Isc 13,7 A · TcVoc -0,28%/°C.
Wählen Sie das Modul, das ersetzt werden soll
102 Module gefunden · 4237 Module ausgeschlossen
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.13 V | 0,2% |
| Vmpp | 42.64 V | 42.57 V | 0,2% |
| Isc | 13.7 A | 13.67 A | 0,2% |
| Impp | 12.9 A | 12.92 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.275 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.45 V | 0,5% |
| Vmpp | 42.64 V | 42.93 V | 0,7% |
| Isc | 13.7 A | 13.73 A | 0,2% |
| Impp | 12.9 A | 12.93 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0,000 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 49.98 V | 0,5% |
| Vmpp | 42.64 V | 42.35 V | 0,7% |
| Isc | 13.7 A | 13.66 A | 0,3% |
| Impp | 12.9 A | 12.87 A | 0,2% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0,000 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.01 V | 0,4% |
| Vmpp | 42.64 V | 42.38 V | 0,6% |
| Isc | 13.7 A | 13.62 A | 0,6% |
| Impp | 12.9 A | 12.86 A | 0,3% |
| TcVoc | -0.28 %/°C | -0.275 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.1 V | 0,2% |
| Vmpp | 42.64 V | 42.13 V | 1,2% |
| Isc | 13.7 A | 13.9 A | 1,5% |
| Impp | 12.9 A | 13.06 A | 1,2% |
| TcVoc | -0.28 %/°C | -0.285 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.28 V | 0,1% |
| Vmpp | 42.64 V | 42.42 V | 0,5% |
| Isc | 13.7 A | 14.21 A | 3,7% |
| Impp | 12.9 A | 13.32 A | 3,3% |
| TcVoc | -0.28 %/°C | -0.275 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
545 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.2 V | 0,0% |
| Vmpp | 42.64 V | 42.1 V | 1,3% |
| Isc | 13.7 A | 13.67 A | 0,2% |
| Impp | 12.9 A | 12.95 A | 0,4% |
| TcVoc | -0.28 %/°C | -0.268 %/°C | ±0,012 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0,020 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.15 V | 0,1% |
| Vmpp | 42.64 V | 42.27 V | 0,9% |
| Isc | 13.7 A | 14.14 A | 3,2% |
| Impp | 12.9 A | 13.25 A | 2,7% |
| TcVoc | -0.28 %/°C | -0.275 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 49.75 V | 0,9% |
| Vmpp | 42.64 V | 42.06 V | 1,4% |
| Isc | 13.7 A | 13.63 A | 0,5% |
| Impp | 12.9 A | 12.84 A | 0,5% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0,000 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.68 V | 0,9% |
| Vmpp | 42.64 V | 43.22 V | 1,4% |
| Isc | 13.7 A | 13.76 A | 0,4% |
| Impp | 12.9 A | 12.96 A | 0,5% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0,000 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 49.9 V | 0,6% |
| Vmpp | 42.64 V | 42.15 V | 1,1% |
| Isc | 13.7 A | 13.57 A | 0,9% |
| Impp | 12.9 A | 12.81 A | 0,7% |
| TcVoc | -0.28 %/°C | -0.275 %/°C | ±0,005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0,010 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.22 V | 50.1 V | 0,2% |
| Vmpp | 42.64 V | 42.42 V | 0,5% |
| Isc | 13.7 A | 14.24 A | 3,9% |
| Impp | 12.9 A | 13.32 A | 3,3% |
| TcVoc | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
50,22 V
Vmpp
42,64 V
Isc
13,7 A
Impp
12,9 A
TcVoc
-0,28 %/°C
TcPmax
-0,36 %/°C
Pmax
550 W
Cells
144
Länge
2290 mm
Breite
1146 mm
Rahmentiefe
30 mm
Gewicht
27,6 kg
Das GCL-M10/72H 550 ist ein 550 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| GCL-M10/72H 540 | 540 W | 49.75 V | 13.63 A |
| GCL-M10/72H 545 | 545 W | 49.98 V | 13.66 A |
| GCL-M10/72H 555 | 555 W | 50.45 V | 13.73 A |
| GCL-M10/72H 560 | 560 W | 50.68 V | 13.76 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 50,22 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,28%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original GCL-M10/72H 550 übereinstimmen.