460 W TOPCon Solarmodul mit 96 Zellen. Voc 35,51 V · Isc 16,06 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
200 Module gefunden · 4139 Module ausgeschlossen
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.42 V | 0,3% |
| Vmpp | 30.15 V | 30.14 V | 0,0% |
| Isc | 16.06 A | 16 A | 0,4% |
| Impp | 15.26 A | 15.1 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.57 V | 0,2% |
| Vmpp | 30.15 V | 30.21 V | 0,2% |
| Isc | 16.06 A | 16 A | 0,4% |
| Impp | 15.26 A | 15.06 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.5 V | 0,0% |
| Vmpp | 30.15 V | 30.3 V | 0,5% |
| Isc | 16.06 A | 16.22 A | 1,0% |
| Impp | 15.26 A | 15.51 A | 1,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.59 V | 0,2% |
| Vmpp | 30.15 V | 30.1 V | 0,2% |
| Isc | 16.06 A | 16.22 A | 1,0% |
| Impp | 15.26 A | 15.12 A | 0,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.4 V | 0,3% |
| Vmpp | 30.15 V | 30.2 V | 0,2% |
| Isc | 16.06 A | 16.18 A | 0,7% |
| Impp | 15.26 A | 15.4 A | 0,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.4 V | 0,3% |
| Vmpp | 30.15 V | 29.9 V | 0,8% |
| Isc | 16.06 A | 16.14 A | 0,5% |
| Impp | 15.26 A | 15.06 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.37 V | 0,4% |
| Vmpp | 30.15 V | 30.04 V | 0,4% |
| Isc | 16.06 A | 15.92 A | 0,9% |
| Impp | 15.26 A | 14.98 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.6 V | 0,3% |
| Vmpp | 30.15 V | 30.4 V | 0,8% |
| Isc | 16.06 A | 16.26 A | 1,2% |
| Impp | 15.26 A | 15.63 A | 2,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.48 V | 0,1% |
| Vmpp | 30.15 V | 29.87 V | 0,9% |
| Isc | 16.06 A | 15.6 A | 2,9% |
| Impp | 15.26 A | 14.9 A | 2,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.72 V | 0,6% |
| Vmpp | 30.15 V | 30.36 V | 0,7% |
| Isc | 16.06 A | 16.13 A | 0,4% |
| Impp | 15.26 A | 15.32 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.31 V | 0,6% |
| Vmpp | 30.15 V | 30.34 V | 0,6% |
| Isc | 16.06 A | 16 A | 0,4% |
| Impp | 15.26 A | 15.16 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0,010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.51 V | 35.38 V | 0,4% |
| Vmpp | 30.15 V | 30.27 V | 0,4% |
| Isc | 16.06 A | 16.09 A | 0,2% |
| Impp | 15.26 A | 15.05 A | 1,4% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
35,51 V
Vmpp
30,15 V
Isc
16,06 A
Impp
15,26 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
460 W
Cells
96
Bifaciality
80%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24,5 kg
Das GCL-NT12R/48GDF 460 ist ein 460 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| GCL-NT12R/48GDF 465 | 465 W | 35.72 V | 16.13 A |
| GCL-NT12R/48GDF 470 | 470 W | 35.92 V | 16.2 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 35,51 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original GCL-NT12R/48GDF 460 übereinstimmen.