450 W TOPCon Solarmodul mit 108 Zellen. Voc 40,1 V · Isc 14,45 A · TcVoc -0,23%/°C.
Wählen Sie das Modul, das ersetzt werden soll
179 Module gefunden · 4160 Module ausgeschlossen
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.14 V | 0,1% |
| Vmpp | 33.64 V | 33.53 V | 0,3% |
| Isc | 14.45 A | 14.03 A | 2,9% |
| Impp | 13.38 A | 13.57 A | 1,4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.9 V | 0,5% |
| Vmpp | 33.64 V | 33.44 V | 0,6% |
| Isc | 14.45 A | 14.37 A | 0,6% |
| Impp | 13.38 A | 13.31 A | 0,5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.08 V | 0,0% |
| Vmpp | 33.64 V | 33.48 V | 0,5% |
| Isc | 14.45 A | 14.3 A | 1,0% |
| Impp | 13.38 A | 13.59 A | 1,6% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.97 V | 0,3% |
| Vmpp | 33.64 V | 33.39 V | 0,7% |
| Isc | 14.45 A | 13.94 A | 3,5% |
| Impp | 13.38 A | 13.48 A | 0,7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.16 V | 0,1% |
| Vmpp | 33.64 V | 33.84 V | 0,6% |
| Isc | 14.45 A | 14.46 A | 0,1% |
| Impp | 13.38 A | 13.6 A | 1,6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.94 V | 0,4% |
| Vmpp | 33.64 V | 33.64 V | 0,0% |
| Isc | 14.45 A | 14.43 A | 0,1% |
| Impp | 13.38 A | 13.53 A | 1,1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.98 V | 0,3% |
| Vmpp | 33.64 V | 33.42 V | 0,7% |
| Isc | 14.45 A | 14.45 A | 0,0% |
| Impp | 13.38 A | 13.61 A | 1,7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.98 V | 0,3% |
| Vmpp | 33.64 V | 33.23 V | 1,2% |
| Isc | 14.45 A | 14.25 A | 1,4% |
| Impp | 13.38 A | 13.54 A | 1,2% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.37 V | 0,7% |
| Vmpp | 33.64 V | 33.72 V | 0,2% |
| Isc | 14.45 A | 14.36 A | 0,6% |
| Impp | 13.38 A | 13.64 A | 1,9% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 39.7 V | 1,0% |
| Vmpp | 33.64 V | 33.24 V | 1,2% |
| Isc | 14.45 A | 14.3 A | 1,0% |
| Impp | 13.38 A | 13.24 A | 1,0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.05 V | 0,1% |
| Vmpp | 33.64 V | 33.71 V | 0,2% |
| Isc | 14.45 A | 14.1 A | 2,4% |
| Impp | 13.38 A | 13.2 A | 1,3% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
470 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.1 V | 40.01 V | 0,2% |
| Vmpp | 33.64 V | 33.58 V | 0,2% |
| Isc | 14.45 A | 14.76 A | 2,1% |
| Impp | 13.38 A | 13.99 A | 4,6% |
| TcVoc | -0.23 %/°C | -0.22 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.26 %/°C | ±0,020 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
40,1 V
Vmpp
33,64 V
Isc
14,45 A
Impp
13,38 A
TcVoc
-0,23 %/°C
TcPmax
-0,28 %/°C
Pmax
450 W
Cells
108
Bifaciality
80%
Länge
1722 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24 kg
Das Horay Solar HS450TC-MHO-D ist ein 450 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| HS430TC-MHO-D | 430 W | 39.3 V | 14.15 A |
| HS435TC-MHO-D | 435 W | 39.5 V | 14.22 A |
| HS440TC-MHO-D | 440 W | 39.7 V | 14.3 A |
| HS445TC-MHO-D | 445 W | 39.9 V | 14.37 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 40,1 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,23%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Horay Solar HS450TC-MHO-D übereinstimmen.