465 W TOPCon Solarmodul mit 96 Zellen. Voc 36,56 V · Isc 16,16 A · TcVoc -0,23%/°C.
Wählen Sie das Modul, das ersetzt werden soll
190 Module gefunden · 3520 Module ausgeschlossen
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.39 V | 0,5% |
| Vmpp | 30.38 V | 30.24 V | 0,5% |
| Isc | 16.16 A | 16.07 A | 0,6% |
| Impp | 15.3 A | 15.21 A | 0,6% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.3 V | 0,7% |
| Vmpp | 30.38 V | 30.6 V | 0,7% |
| Isc | 16.16 A | 16.31 A | 0,9% |
| Impp | 15.3 A | 15.37 A | 0,5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.1 V | 1,3% |
| Vmpp | 30.38 V | 30.4 V | 0,1% |
| Isc | 16.16 A | 16.24 A | 0,5% |
| Impp | 15.3 A | 15.3 A | 0,0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.47 V | 0,2% |
| Vmpp | 30.38 V | 30.37 V | 0,0% |
| Isc | 16.16 A | 15.7 A | 2,8% |
| Impp | 15.3 A | 14.99 A | 2,0% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.21 V | 1,0% |
| Vmpp | 30.38 V | 30.1 V | 0,9% |
| Isc | 16.16 A | 15.97 A | 1,2% |
| Impp | 15.3 A | 15.12 A | 1,2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.68 V | 0,3% |
| Vmpp | 30.38 V | 30.6 V | 0,7% |
| Isc | 16.16 A | 15.76 A | 2,5% |
| Impp | 15.3 A | 15.04 A | 1,7% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.61 V | 0,1% |
| Vmpp | 30.38 V | 30.24 V | 0,5% |
| Isc | 16.16 A | 16.44 A | 1,7% |
| Impp | 15.3 A | 15.55 A | 1,6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.61 V | 0,1% |
| Vmpp | 30.38 V | 30.24 V | 0,5% |
| Isc | 16.16 A | 16.44 A | 1,7% |
| Impp | 15.3 A | 15.55 A | 1,6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.61 V | 0,1% |
| Vmpp | 30.38 V | 30.24 V | 0,5% |
| Isc | 16.16 A | 16.44 A | 1,7% |
| Impp | 15.3 A | 15.55 A | 1,6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.58 V | 0,1% |
| Vmpp | 30.38 V | 30.47 V | 0,3% |
| Isc | 16.16 A | 15.78 A | 2,4% |
| Impp | 15.3 A | 14.93 A | 2,4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.35 V | 0,6% |
| Vmpp | 30.38 V | 30.94 V | 1,8% |
| Isc | 16.16 A | 16.12 A | 0,2% |
| Impp | 15.3 A | 15.03 A | 1,8% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.56 V | 36.44 V | 0,3% |
| Vmpp | 30.38 V | 30.1 V | 0,9% |
| Isc | 16.16 A | 16.34 A | 1,1% |
| Impp | 15.3 A | 15.46 A | 1,0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
36,56 V
Vmpp
30,38 V
Isc
16,16 A
Impp
15,3 A
TcVoc
-0,23 %/°C
TcPmax
-0,28 %/°C
Pmax
465 W
Cells
96
Bifaciality
80%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24,5 kg
Das Horay Solar HS465TC-MHC-D ist ein 465 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| HS445TC-MHC-D | 445 W | 35.87 V | 15.77 A |
| HS450TC-MHC-D | 450 W | 36.04 V | 15.87 A |
| HS455TC-MHC-D | 455 W | 36.21 V | 15.97 A |
| HS460TC-MHC-D | 460 W | 36.39 V | 16.07 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 36,56 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,23%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Horay Solar HS465TC-MHC-D übereinstimmen.