520 W TOPCon Solarmodul mit 120 Zellen. Voc 44,01 V · Isc 14,83 A · TcVoc -0,23%/°C.
Wählen Sie das Modul, das ersetzt werden soll
72 Module gefunden · 4267 Module ausgeschlossen
500 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 44.06 V | 0,1% |
| Vmpp | 37.33 V | 37.24 V | 0,2% |
| Isc | 14.83 A | 14.5 A | 2,2% |
| Impp | 13.93 A | 13.43 A | 3,6% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 44.1 V | 0,2% |
| Vmpp | 37.33 V | 36.8 V | 1,4% |
| Isc | 14.83 A | 14.64 A | 1,3% |
| Impp | 13.93 A | 13.86 A | 0,5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
515 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.68 V | 0,7% |
| Vmpp | 37.33 V | 37.05 V | 0,8% |
| Isc | 14.83 A | 14.8 A | 0,2% |
| Impp | 13.93 A | 13.9 A | 0,2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.88 V | 0,3% |
| Vmpp | 37.33 V | 36.62 V | 1,9% |
| Isc | 14.83 A | 14.57 A | 1,8% |
| Impp | 13.93 A | 13.79 A | 1,0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.62 V | 0,9% |
| Vmpp | 37.33 V | 37 V | 0,9% |
| Isc | 14.83 A | 14.68 A | 1,0% |
| Impp | 13.93 A | 13.78 A | 1,1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.9 V | 0,2% |
| Vmpp | 37.33 V | 37.3 V | 0,1% |
| Isc | 14.83 A | 14.54 A | 2,0% |
| Impp | 13.93 A | 13.54 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.9 V | 0,2% |
| Vmpp | 37.33 V | 37.3 V | 0,1% |
| Isc | 14.83 A | 14.54 A | 2,0% |
| Impp | 13.93 A | 13.54 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 44.1 V | 0,2% |
| Vmpp | 37.33 V | 37.5 V | 0,5% |
| Isc | 14.83 A | 14.6 A | 1,6% |
| Impp | 13.93 A | 13.6 A | 2,4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.9 V | 0,2% |
| Vmpp | 37.33 V | 37.3 V | 0,1% |
| Isc | 14.83 A | 14.54 A | 2,0% |
| Impp | 13.93 A | 13.54 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 44.1 V | 0,2% |
| Vmpp | 37.33 V | 37.5 V | 0,5% |
| Isc | 14.83 A | 14.6 A | 1,6% |
| Impp | 13.93 A | 13.6 A | 2,4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 43.9 V | 0,2% |
| Vmpp | 37.33 V | 37.3 V | 0,1% |
| Isc | 14.83 A | 14.54 A | 2,0% |
| Impp | 13.93 A | 13.54 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.01 V | 44.1 V | 0,2% |
| Vmpp | 37.33 V | 37.5 V | 0,5% |
| Isc | 14.83 A | 14.6 A | 1,6% |
| Impp | 13.93 A | 13.6 A | 2,4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
44,01 V
Vmpp
37,33 V
Isc
14,83 A
Impp
13,93 A
TcVoc
-0,23 %/°C
TcPmax
-0,28 %/°C
Pmax
520 W
Cells
120
Bifaciality
80%
Länge
1994 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
28 kg
Das Horay Solar HS520TC-MHB-D ist ein 520 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| HS505TC-MHB-D | 505 W | 43.42 V | 14.6 A |
| HS510TC-MHB-D | 510 W | 43.62 V | 14.68 A |
| HS515TC-MHB-D | 515 W | 43.68 V | 14.8 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 120), Voc nahe 44,01 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,23%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Horay Solar HS520TC-MHB-D übereinstimmen.