545 W TOPCon Solarmodul mit 132 Zellen. Voc 48,52 V · Isc 14,41 A · TcVoc -0,23%/°C.
Wählen Sie das Modul, das ersetzt werden soll
23 Module gefunden · 4316 Module ausgeschlossen
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.76 V | 0,5% |
| Vmpp | 40.84 V | 41.04 V | 0,5% |
| Isc | 14.41 A | 14.47 A | 0,4% |
| Impp | 13.34 A | 13.4 A | 0,4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.27 V | 0,5% |
| Vmpp | 40.84 V | 40.64 V | 0,5% |
| Isc | 14.41 A | 14.35 A | 0,4% |
| Impp | 13.34 A | 13.29 A | 0,4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.51 V | 0,0% |
| Vmpp | 40.84 V | 40.48 V | 0,9% |
| Isc | 14.41 A | 14.61 A | 1,4% |
| Impp | 13.34 A | 13.83 A | 3,7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
530 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.57 V | 0,1% |
| Vmpp | 40.84 V | 40.22 V | 1,5% |
| Isc | 14.41 A | 14 A | 2,8% |
| Impp | 13.34 A | 13.18 A | 1,2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.27 V | 0,5% |
| Vmpp | 40.84 V | 40.28 V | 1,4% |
| Isc | 14.41 A | 14.56 A | 1,0% |
| Impp | 13.34 A | 13.78 A | 3,3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
535 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.72 V | 0,4% |
| Vmpp | 40.84 V | 40.38 V | 1,1% |
| Isc | 14.41 A | 14.07 A | 2,4% |
| Impp | 13.34 A | 13.25 A | 0,7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
540 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.87 V | 0,7% |
| Vmpp | 40.84 V | 40.53 V | 0,8% |
| Isc | 14.41 A | 14.15 A | 1,8% |
| Impp | 13.34 A | 13.33 A | 0,1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.04 V | 1,0% |
| Vmpp | 40.84 V | 40.44 V | 1,0% |
| Isc | 14.41 A | 14.29 A | 0,8% |
| Impp | 13.34 A | 13.23 A | 0,8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.05 V | 1,0% |
| Vmpp | 40.84 V | 40.76 V | 0,2% |
| Isc | 14.41 A | 14.76 A | 2,4% |
| Impp | 13.34 A | 13.86 A | 3,9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 47.98 V | 1,1% |
| Vmpp | 40.84 V | 40.7 V | 0,3% |
| Isc | 14.41 A | 14.65 A | 1,7% |
| Impp | 13.34 A | 13.76 A | 3,1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
525 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.42 V | 0,2% |
| Vmpp | 40.84 V | 40.06 V | 1,9% |
| Isc | 14.41 A | 13.93 A | 3,3% |
| Impp | 13.34 A | 13.11 A | 1,7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.52 V | 48.07 V | 0,9% |
| Vmpp | 40.84 V | 40.11 V | 1,8% |
| Isc | 14.41 A | 14.48 A | 0,5% |
| Impp | 13.34 A | 13.71 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
48,52 V
Vmpp
40,84 V
Isc
14,41 A
Impp
13,34 A
TcVoc
-0,23 %/°C
TcPmax
-0,28 %/°C
Pmax
545 W
Cells
132
Länge
2094 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24,5 kg
Das Horay Solar HS545TC-MHO ist ein 545 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| HS530TC-MHO | 530 W | 47.81 V | 14.22 A |
| HS535TC-MHO | 535 W | 48.04 V | 14.29 A |
| HS540TC-MHO | 540 W | 48.27 V | 14.35 A |
| HS550TC-MHO | 550 W | 48.76 V | 14.47 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 48,52 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,23%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Horay Solar HS545TC-MHO übereinstimmen.