570 W TOPCon Solarmodul mit 120 Zellen. Voc 45,05 V · Isc 16,08 A · TcVoc -0,23%/°C.
Wählen Sie das Modul, das ersetzt werden soll
27 Module gefunden · 3683 Module ausgeschlossen
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.27 V | 0,5% |
| Vmpp | 37.44 V | 37.62 V | 0,5% |
| Isc | 16.08 A | 16.14 A | 0,4% |
| Impp | 15.22 A | 15.28 A | 0,4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.83 V | 0,5% |
| Vmpp | 37.44 V | 37.26 V | 0,5% |
| Isc | 16.08 A | 16.01 A | 0,4% |
| Impp | 15.22 A | 15.16 A | 0,4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.07 V | 0,0% |
| Vmpp | 37.44 V | 37.61 V | 0,5% |
| Isc | 16.08 A | 16.01 A | 0,4% |
| Impp | 15.22 A | 15.16 A | 0,4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.48 V | 1,0% |
| Vmpp | 37.44 V | 37.8 V | 1,0% |
| Isc | 16.08 A | 16.2 A | 0,7% |
| Impp | 15.22 A | 15.34 A | 0,8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.62 V | 1,0% |
| Vmpp | 37.44 V | 37.08 V | 1,0% |
| Isc | 16.08 A | 15.95 A | 0,8% |
| Impp | 15.22 A | 15.1 A | 0,8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0,000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.87 V | 0,4% |
| Vmpp | 37.44 V | 37.41 V | 0,1% |
| Isc | 16.08 A | 15.96 A | 0,7% |
| Impp | 15.22 A | 15.11 A | 0,7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.27 V | 0,5% |
| Vmpp | 37.44 V | 37.81 V | 1,0% |
| Isc | 16.08 A | 16.06 A | 0,1% |
| Impp | 15.22 A | 15.21 A | 0,1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0,1% |
| Vmpp | 37.44 V | 37.94 V | 1,3% |
| Isc | 16.08 A | 15.7 A | 2,4% |
| Impp | 15.22 A | 14.76 A | 3,0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0,1% |
| Vmpp | 37.44 V | 37.94 V | 1,3% |
| Isc | 16.08 A | 15.7 A | 2,4% |
| Impp | 15.22 A | 14.76 A | 3,0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0,1% |
| Vmpp | 37.44 V | 37.94 V | 1,3% |
| Isc | 16.08 A | 15.7 A | 2,4% |
| Impp | 15.22 A | 14.76 A | 3,0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.67 V | 0,8% |
| Vmpp | 37.44 V | 37.21 V | 0,6% |
| Isc | 16.08 A | 15.91 A | 1,1% |
| Impp | 15.22 A | 15.05 A | 1,1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.15 V | 0,2% |
| Vmpp | 37.44 V | 38.18 V | 2,0% |
| Isc | 16.08 A | 15.75 A | 2,1% |
| Impp | 15.22 A | 14.8 A | 2,8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0,020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
45,05 V
Vmpp
37,44 V
Isc
16,08 A
Impp
15,22 A
TcVoc
-0,23 %/°C
TcPmax
-0,28 %/°C
Pmax
570 W
Cells
120
Bifaciality
80%
Länge
2178 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
30,5 kg
Das Horay Solar HS570TC-MHC-D ist ein 570 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| HS560TC-MHC-D | 560 W | 44.62 V | 15.95 A |
| HS565TC-MHC-D | 565 W | 44.83 V | 16.01 A |
| HS575TC-MHC-D | 575 W | 45.27 V | 16.14 A |
| HS580TC-MHC-D | 580 W | 45.48 V | 16.2 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 120), Voc nahe 45,05 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,23%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Horay Solar HS570TC-MHC-D übereinstimmen.