610 W TOPCon Solarmodul mit 144 Zellen. Voc 51,86 V · Isc 14,75 A · TcVoc -0,26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
107 Module gefunden · 4232 Module ausgeschlossen
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.66 V | 0,4% |
| Vmpp | 42.94 V | 42.74 V | 0,5% |
| Isc | 14.75 A | 14.68 A | 0,5% |
| Impp | 14.21 A | 14.16 A | 0,4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 52.06 V | 0,4% |
| Vmpp | 42.94 V | 43.14 V | 0,5% |
| Isc | 14.75 A | 14.82 A | 0,5% |
| Impp | 14.21 A | 14.26 A | 0,4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.89 V | 0,1% |
| Vmpp | 42.94 V | 42.92 V | 0,0% |
| Isc | 14.75 A | 14.47 A | 1,9% |
| Impp | 14.21 A | 13.75 A | 3,2% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.32 %/°C | ±0,010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.94 V | 0,2% |
| Vmpp | 42.94 V | 43.13 V | 0,4% |
| Isc | 14.75 A | 14.64 A | 0,7% |
| Impp | 14.21 A | 13.91 A | 2,1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.81 V | 0,1% |
| Vmpp | 42.94 V | 43.02 V | 0,2% |
| Isc | 14.75 A | 14.56 A | 1,3% |
| Impp | 14.21 A | 13.83 A | 2,7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.46 V | 0,8% |
| Vmpp | 42.94 V | 42.54 V | 0,9% |
| Isc | 14.75 A | 14.61 A | 0,9% |
| Impp | 14.21 A | 14.1 A | 0,8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 52.26 V | 0,8% |
| Vmpp | 42.94 V | 43.34 V | 0,9% |
| Isc | 14.75 A | 14.88 A | 0,9% |
| Impp | 14.21 A | 14.31 A | 0,7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 52.07 V | 0,4% |
| Vmpp | 42.94 V | 43.24 V | 0,7% |
| Isc | 14.75 A | 14.72 A | 0,2% |
| Impp | 14.21 A | 13.99 A | 1,5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.98 V | 0,2% |
| Vmpp | 42.94 V | 43.35 V | 1,0% |
| Isc | 14.75 A | 14.3 A | 3,1% |
| Impp | 14.21 A | 13.62 A | 4,2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.98 V | 0,2% |
| Vmpp | 42.94 V | 43.35 V | 1,0% |
| Isc | 14.75 A | 14.3 A | 3,1% |
| Impp | 14.21 A | 13.62 A | 4,2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.98 V | 0,2% |
| Vmpp | 42.94 V | 43.35 V | 1,0% |
| Isc | 14.75 A | 14.3 A | 3,1% |
| Impp | 14.21 A | 13.62 A | 4,2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.86 V | 51.98 V | 0,2% |
| Vmpp | 42.94 V | 43.35 V | 1,0% |
| Isc | 14.75 A | 14.3 A | 3,1% |
| Impp | 14.21 A | 13.62 A | 4,2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
51,86 V
Vmpp
42,94 V
Isc
14,75 A
Impp
14,21 A
TcVoc
-0,26 %/°C
TcPmax
-0,31 %/°C
Pmax
610 W
Cells
144
Länge
2279 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
28 kg
Das Inter Energy IE182x182/M/72/610MH ist ein 610 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| IE182x182/M/72/600MH | 600 W | 51.46 V | 14.61 A |
| IE182x182/M/72/605MH | 605 W | 51.66 V | 14.68 A |
| IE182x182/M/72/615MH | 615 W | 52.06 V | 14.82 A |
| IE182x182/M/72/620MH | 620 W | 52.26 V | 14.88 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 51,86 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Inter Energy IE182x182/M/72/610MH übereinstimmen.