540 W TOPCon Solarmodul mit 120 Zellen. Voc 44,33 V · Isc 15,36 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
30 Module gefunden · 4309 Module ausgeschlossen
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.13 V | 0,5% |
| Vmpp | 37.25 V | 37.03 V | 0,6% |
| Isc | 15.36 A | 15.31 A | 0,3% |
| Impp | 14.5 A | 14.45 A | 0,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.27 V | 0,1% |
| Vmpp | 37.25 V | 36.81 V | 1,2% |
| Isc | 15.36 A | 15.83 A | 3,1% |
| Impp | 14.5 A | 14.95 A | 3,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.47 V | 0,3% |
| Vmpp | 37.25 V | 37.01 V | 0,6% |
| Isc | 15.36 A | 15.88 A | 3,4% |
| Impp | 14.5 A | 15 A | 3,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 43.93 V | 0,9% |
| Vmpp | 37.25 V | 36.81 V | 1,2% |
| Isc | 15.36 A | 15.26 A | 0,7% |
| Impp | 14.5 A | 14.4 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.67 V | 0,8% |
| Vmpp | 37.25 V | 37.21 V | 0,1% |
| Isc | 15.36 A | 15.91 A | 3,6% |
| Impp | 14.5 A | 15.05 A | 3,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 44.5 V | 0,4% |
| Vmpp | 37.25 V | 37.9 V | 1,7% |
| Isc | 15.36 A | 14.72 A | 4,2% |
| Impp | 14.5 A | 13.72 A | 5,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
525 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.33 V | 43.73 V | 1,4% |
| Vmpp | 37.25 V | 36.59 V | 1,8% |
| Isc | 15.36 A | 15.21 A | 1,0% |
| Impp | 14.5 A | 14.35 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
44,33 V
Vmpp
37,25 V
Isc
15,36 A
Impp
14,5 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
540 W
Cells
120
Bifaciality
80%
Länge
2063 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
28,8 kg
Das JA Solar JAM60D42-540/LB ist ein 540 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| JAM60D42-515/LB | 515 W | 43.33 V | 15.11 A |
| JAM60D42-520/LB | 520 W | 43.53 V | 15.16 A |
| JAM60D42-525/LB | 525 W | 43.73 V | 15.21 A |
| JAM60D42-530/LB | 530 W | 43.93 V | 15.26 A |
| JAM60D42-535/LB | 535 W | 44.13 V | 15.31 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 120), Voc nahe 44,33 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original JA Solar JAM60D42-540/LB übereinstimmen.