575 W PERC Solarmodul mit 144 Zellen. Voc 50,86 V · Isc 14,44 A · TcVoc -0,275%/°C.
Wählen Sie das Modul, das ersetzt werden soll
78 Module gefunden · 4261 Module ausgeschlossen
570 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.68 V | 0,4% |
| Vmpp | 42.05 V | 41.87 V | 0,4% |
| Isc | 14.44 A | 14.37 A | 0,5% |
| Impp | 13.67 A | 13.62 A | 0,4% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
580 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 51.04 V | 0,4% |
| Vmpp | 42.05 V | 42.24 V | 0,5% |
| Isc | 14.44 A | 14.5 A | 0,4% |
| Impp | 13.67 A | 13.73 A | 0,4% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.5 V | 0,7% |
| Vmpp | 42.05 V | 41.68 V | 0,9% |
| Isc | 14.44 A | 14.31 A | 0,9% |
| Impp | 13.67 A | 13.56 A | 0,8% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 51.22 V | 0,7% |
| Vmpp | 42.05 V | 42.42 V | 0,9% |
| Isc | 14.44 A | 14.56 A | 0,8% |
| Impp | 13.67 A | 13.79 A | 0,9% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.32 V | 1,1% |
| Vmpp | 42.05 V | 41.49 V | 1,3% |
| Isc | 14.44 A | 14.25 A | 1,3% |
| Impp | 13.67 A | 13.5 A | 1,2% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.28 V | 1,1% |
| Vmpp | 42.05 V | 42.42 V | 0,9% |
| Isc | 14.44 A | 14.21 A | 1,6% |
| Impp | 13.67 A | 13.32 A | 2,6% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.6 V | 0,5% |
| Vmpp | 42.05 V | 42.5 V | 1,1% |
| Isc | 14.44 A | 14.12 A | 2,2% |
| Impp | 13.67 A | 13.06 A | 4,5% |
| TcVoc | -0.275 %/°C | -0.268 %/°C | ±0,007 %/°C |
| TcPmax | -0.35 %/°C | -0.34 %/°C | ±0,010 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.15 V | 1,4% |
| Vmpp | 42.05 V | 42.27 V | 0,5% |
| Isc | 14.44 A | 14.14 A | 2,1% |
| Impp | 13.67 A | 13.25 A | 3,1% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.02 V | 1,7% |
| Vmpp | 42.05 V | 42.11 V | 0,1% |
| Isc | 14.44 A | 14.07 A | 2,6% |
| Impp | 13.67 A | 13.18 A | 3,6% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.74 V | 0,2% |
| Vmpp | 42.05 V | 42.07 V | 0,0% |
| Isc | 14.44 A | 14.31 A | 0,9% |
| Impp | 13.67 A | 13.55 A | 0,9% |
| TcVoc | -0.275 %/°C | -0.25 %/°C | ±0,025 %/°C |
| TcPmax | -0.35 %/°C | -0.3 %/°C | ±0,050 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 50.3 V | 1,1% |
| Vmpp | 42.05 V | 42.42 V | 0,9% |
| Isc | 14.44 A | 14.16 A | 1,9% |
| Impp | 13.67 A | 13.32 A | 2,6% |
| TcVoc | -0.275 %/°C | -0.265 %/°C | ±0,010 %/°C |
| TcPmax | -0.35 %/°C | -0.34 %/°C | ±0,010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.86 V | 51.02 V | 0,3% |
| Vmpp | 42.05 V | 42.37 V | 0,8% |
| Isc | 14.44 A | 14.47 A | 0,2% |
| Impp | 13.67 A | 13.69 A | 0,1% |
| TcVoc | -0.275 %/°C | -0.25 %/°C | ±0,025 %/°C |
| TcPmax | -0.35 %/°C | -0.3 %/°C | ±0,050 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
50,86 V
Vmpp
42,05 V
Isc
14,44 A
Impp
13,67 A
TcVoc
-0,275 %/°C
TcPmax
-0,35 %/°C
Pmax
575 W
Cells
144
Länge
2333 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
28 kg
Das JA Solar JAM72S30-575/LR ist ein 575 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| JAM72S30-560/LR | 560 W | 50.32 V | 14.25 A |
| JAM72S30-565/LR | 565 W | 50.5 V | 14.31 A |
| JAM72S30-570/LR | 570 W | 50.68 V | 14.37 A |
| JAM72S30-580/LR | 580 W | 51.04 V | 14.5 A |
| JAM72S30-585/LR | 585 W | 51.22 V | 14.56 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 50,86 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,275%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original JA Solar JAM72S30-575/LR übereinstimmen.