730 W TOPCon Solarmodul mit 132 Zellen. Voc 49,36 V · Isc 18,81 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
153 Module gefunden · 4186 Module ausgeschlossen
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.37 V | 0,0% |
| Vmpp | 41.11 V | 40.98 V | 0,3% |
| Isc | 18.81 A | 18.63 A | 1,0% |
| Impp | 17.76 A | 17.69 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.38 V | 0,0% |
| Vmpp | 41.11 V | 41.27 V | 0,4% |
| Isc | 18.81 A | 18.65 A | 0,9% |
| Impp | 17.76 A | 17.58 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.3 V | 0,1% |
| Vmpp | 41.11 V | 41.4 V | 0,7% |
| Isc | 18.81 A | 18.84 A | 0,2% |
| Impp | 17.76 A | 17.78 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.52 V | 0,3% |
| Vmpp | 41.11 V | 41.23 V | 0,3% |
| Isc | 18.81 A | 18.88 A | 0,4% |
| Impp | 17.76 A | 17.83 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.2 V | 0,3% |
| Vmpp | 41.11 V | 41 V | 0,3% |
| Isc | 18.81 A | 18.74 A | 0,4% |
| Impp | 17.76 A | 17.69 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.2 V | 0,3% |
| Vmpp | 41.11 V | 41.1 V | 0,0% |
| Isc | 18.81 A | 18.6 A | 1,1% |
| Impp | 17.76 A | 17.54 A | 1,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.57 V | 0,4% |
| Vmpp | 41.11 V | 41.24 V | 0,3% |
| Isc | 18.81 A | 18.67 A | 0,7% |
| Impp | 17.76 A | 17.7 A | 0,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.37 V | 0,0% |
| Vmpp | 41.11 V | 40.78 V | 0,8% |
| Isc | 18.81 A | 18.53 A | 1,5% |
| Impp | 17.76 A | 17.42 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.37 V | 0,0% |
| Vmpp | 41.11 V | 40.78 V | 0,8% |
| Isc | 18.81 A | 18.53 A | 1,5% |
| Impp | 17.76 A | 17.42 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.37 V | 0,0% |
| Vmpp | 41.11 V | 40.78 V | 0,8% |
| Isc | 18.81 A | 18.53 A | 1,5% |
| Impp | 17.76 A | 17.42 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.1 V | 0,5% |
| Vmpp | 41.11 V | 41.2 V | 0,2% |
| Isc | 18.81 A | 18.79 A | 0,1% |
| Impp | 17.76 A | 17.75 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.36 V | 49.3 V | 0,1% |
| Vmpp | 41.11 V | 41.33 V | 0,5% |
| Isc | 18.81 A | 18.48 A | 1,8% |
| Impp | 17.76 A | 17.43 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
49,36 V
Vmpp
41,11 V
Isc
18,81 A
Impp
17,76 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
730 W
Cells
132
Bifaciality
80%
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
33 mm
Gewicht
37,5 kg
Das JinkoSolar JKM730N-66HL5-BDV ist ein 730 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| JKM735N-66HL5-BDV | 735 W | 49.52 V | 18.88 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 49,36 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original JinkoSolar JKM730N-66HL5-BDV übereinstimmen.