690 W TOPCon Solarmodul mit 132 Zellen. Voc 48,38 V · Isc 17,88 A · TcVoc -0,22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
22 Module gefunden · 4317 Module ausgeschlossen
685 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.14 V | 0,5% |
| Vmpp | 40.32 V | 40.12 V | 0,5% |
| Isc | 17.88 A | 17.84 A | 0,2% |
| Impp | 17.12 A | 17.08 A | 0,2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.62 V | 0,5% |
| Vmpp | 40.32 V | 40.52 V | 0,5% |
| Isc | 17.88 A | 17.93 A | 0,3% |
| Impp | 17.12 A | 17.16 A | 0,2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
680 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 47.9 V | 1,0% |
| Vmpp | 40.32 V | 39.92 V | 1,0% |
| Isc | 17.88 A | 17.8 A | 0,4% |
| Impp | 17.12 A | 17.04 A | 0,5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.86 V | 1,0% |
| Vmpp | 40.32 V | 40.72 V | 1,0% |
| Isc | 17.88 A | 17.97 A | 0,5% |
| Impp | 17.12 A | 17.2 A | 0,5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
675 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 47.66 V | 1,5% |
| Vmpp | 40.32 V | 39.72 V | 1,5% |
| Isc | 17.88 A | 17.76 A | 0,7% |
| Impp | 17.12 A | 17 A | 0,7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.3 V | 0,2% |
| Vmpp | 40.32 V | 40.3 V | 0,0% |
| Isc | 17.88 A | 18.28 A | 2,2% |
| Impp | 17.12 A | 17.25 A | 0,8% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0,020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.6 V | 0,5% |
| Vmpp | 40.32 V | 40.5 V | 0,4% |
| Isc | 17.88 A | 18.32 A | 2,5% |
| Impp | 17.12 A | 17.29 A | 1,0% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0,020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
670 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 47.42 V | 2,0% |
| Vmpp | 40.32 V | 39.52 V | 2,0% |
| Isc | 17.88 A | 17.72 A | 0,9% |
| Impp | 17.12 A | 16.96 A | 0,9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0,000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0,000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.51 V | 0,3% |
| Vmpp | 40.32 V | 40.71 V | 1,0% |
| Isc | 17.88 A | 18.22 A | 1,9% |
| Impp | 17.12 A | 17.2 A | 0,5% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0,030 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.3 V | 0,2% |
| Vmpp | 40.32 V | 40.6 V | 0,7% |
| Isc | 17.88 A | 18.61 A | 4,1% |
| Impp | 17.12 A | 17.49 A | 2,2% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0,030 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.87 V | 1,0% |
| Vmpp | 40.32 V | 41.2 V | 2,2% |
| Isc | 17.88 A | 18.03 A | 0,8% |
| Impp | 17.12 A | 16.99 A | 0,8% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0,010 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.1 V | 0,6% |
| Vmpp | 40.32 V | 40.4 V | 0,2% |
| Isc | 17.88 A | 18.55 A | 3,7% |
| Impp | 17.12 A | 17.46 A | 2,0% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0,030 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0,050 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
48,38 V
Vmpp
40,32 V
Isc
17,88 A
Impp
17,12 A
TcVoc
-0,22 %/°C
TcPmax
-0,24 %/°C
Pmax
690 W
Cells
132
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
35 mm
Gewicht
38 kg
Das LogicPower LP-690M ist ein 690 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 48,38 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original LogicPower LP-690M übereinstimmen.