420 W TOPCon Solarmodul mit 108 Zellen. Voc 38,02 V · Isc 14,05 A · TcVoc -0,26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
138 Module gefunden · 4201 Module ausgeschlossen
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 37.83 V | 0,5% |
| Vmpp | 31.63 V | 31.44 V | 0,6% |
| Isc | 14.05 A | 13.97 A | 0,6% |
| Impp | 13.28 A | 13.2 A | 0,6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 31.94 V | 1,0% |
| Isc | 14.05 A | 13.95 A | 0,7% |
| Impp | 13.28 A | 13.15 A | 1,0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 37.91 V | 0,3% |
| Vmpp | 31.63 V | 31.94 V | 1,0% |
| Isc | 14.05 A | 13.95 A | 0,7% |
| Impp | 13.28 A | 13.15 A | 1,0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 31.94 V | 1,0% |
| Isc | 14.05 A | 13.95 A | 0,7% |
| Impp | 13.28 A | 13.15 A | 1,0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 31.94 V | 1,0% |
| Isc | 14.05 A | 13.95 A | 0,7% |
| Impp | 13.28 A | 13.15 A | 1,0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 31.51 V | 0,4% |
| Isc | 14.05 A | 14.07 A | 0,1% |
| Impp | 13.28 A | 13.33 A | 0,4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 32.14 V | 1,6% |
| Isc | 14.05 A | 14.03 A | 0,1% |
| Impp | 13.28 A | 13.23 A | 0,4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.11 V | 0,2% |
| Vmpp | 31.63 V | 31.51 V | 0,4% |
| Isc | 14.05 A | 14.07 A | 0,1% |
| Impp | 13.28 A | 13.33 A | 0,4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 37.9 V | 0,3% |
| Vmpp | 31.63 V | 31.9 V | 0,9% |
| Isc | 14.05 A | 13.98 A | 0,5% |
| Impp | 13.28 A | 13.17 A | 0,8% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 38.1 V | 0,2% |
| Vmpp | 31.63 V | 32.1 V | 1,5% |
| Isc | 14.05 A | 14.05 A | 0,0% |
| Impp | 13.28 A | 13.24 A | 0,3% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 37.92 V | 0,3% |
| Vmpp | 31.63 V | 31.32 V | 1,0% |
| Isc | 14.05 A | 13.99 A | 0,4% |
| Impp | 13.28 A | 13.25 A | 0,2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.02 V | 37.71 V | 0,8% |
| Vmpp | 31.63 V | 31.74 V | 0,3% |
| Isc | 14.05 A | 13.88 A | 1,2% |
| Impp | 13.28 A | 13.08 A | 1,5% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
38,02 V
Vmpp
31,63 V
Isc
14,05 A
Impp
13,28 A
TcVoc
-0,26 %/°C
TcPmax
-0,31 %/°C
Pmax
420 W
Cells
108
Länge
1722 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
21,5 kg
Das Perlight Solar PLM-420H8NB-108 ist ein 420 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| PLM-415H8NB-108 | 415 W | 37.83 V | 13.97 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 38,02 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Perlight Solar PLM-420H8NB-108 übereinstimmen.