445 W HJT Solarmodul mit 108 Zellen. Voc 42,18 V · Isc 13,1 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
13 Module gefunden · 4326 Module ausgeschlossen
440 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.91 V | 0,6% |
| Vmpp | 35.38 V | 35.12 V | 0,7% |
| Isc | 13.1 A | 13.05 A | 0,4% |
| Impp | 12.58 A | 12.53 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
450 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 42.44 V | 0,6% |
| Vmpp | 35.38 V | 35.63 V | 0,7% |
| Isc | 13.1 A | 13.15 A | 0,4% |
| Impp | 12.58 A | 12.63 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
435 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.64 V | 1,3% |
| Vmpp | 35.38 V | 34.86 V | 1,5% |
| Isc | 13.1 A | 13 A | 0,8% |
| Impp | 12.58 A | 12.48 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
430 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.37 V | 1,9% |
| Vmpp | 35.38 V | 34.6 V | 2,2% |
| Isc | 13.1 A | 12.95 A | 1,1% |
| Impp | 12.58 A | 12.43 A | 1,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.2 V | 2,3% |
| Vmpp | 35.38 V | 34.34 V | 2,9% |
| Isc | 13.1 A | 13.82 A | 5,5% |
| Impp | 12.58 A | 13.25 A | 5,3% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.31 %/°C | ±0,010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.3 V | 2,1% |
| Vmpp | 35.38 V | 34.56 V | 2,3% |
| Isc | 13.1 A | 13.65 A | 4,2% |
| Impp | 12.58 A | 12.88 A | 2,4% |
| TcVoc | -0.25 %/°C | -0.27 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0,040 %/°C |
450 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 40.94 V | 2,9% |
| Vmpp | 35.38 V | 34.5 V | 2,5% |
| Isc | 13.1 A | 14.12 A | 7,8% |
| Impp | 12.58 A | 13.05 A | 3,7% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
455 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41 V | 2,8% |
| Vmpp | 35.38 V | 34.56 V | 2,3% |
| Isc | 13.1 A | 14.22 A | 8,5% |
| Impp | 12.58 A | 13.17 A | 4,7% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
460 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.06 V | 2,7% |
| Vmpp | 35.38 V | 34.62 V | 2,1% |
| Isc | 13.1 A | 14.25 A | 8,8% |
| Impp | 12.58 A | 13.29 A | 5,6% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
455 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41 V | 2,8% |
| Vmpp | 35.38 V | 34.56 V | 2,3% |
| Isc | 13.1 A | 14.22 A | 8,5% |
| Impp | 12.58 A | 13.17 A | 4,7% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
460 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.06 V | 2,7% |
| Vmpp | 35.38 V | 34.62 V | 2,1% |
| Isc | 13.1 A | 14.25 A | 8,8% |
| Impp | 12.58 A | 13.29 A | 5,6% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
465 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 42.18 V | 41.12 V | 2,5% |
| Vmpp | 35.38 V | 34.68 V | 2,0% |
| Isc | 13.1 A | 14.29 A | 9,1% |
| Impp | 12.58 A | 13.41 A | 6,6% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0,030 %/°C |
| TcPmax | -0.3 %/°C | -0.26 %/°C | ±0,040 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
42,18 V
Vmpp
35,38 V
Isc
13,1 A
Impp
12,58 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
445 W
Cells
108
Länge
1722 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
22 kg
Das Perlight Solar PLM-445DH8N-108 ist ein 445 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| PLM-430DH8N-108 | 430 W | 41.37 V | 12.95 A |
| PLM-435DH8N-108 | 435 W | 41.64 V | 13 A |
| PLM-440DH8N-108 | 440 W | 41.91 V | 13.05 A |
| PLM-450DH8N-108 | 450 W | 42.44 V | 13.15 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 42,18 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Perlight Solar PLM-445DH8N-108 übereinstimmen.