585 W TOPCon Solarmodul mit 144 Zellen. Voc 53 V · Isc 13,54 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
113 Module gefunden · 4226 Module ausgeschlossen
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.8 V | 0,4% |
| Vmpp | 45.23 V | 45.03 V | 0,4% |
| Isc | 13.54 A | 13.5 A | 0,3% |
| Impp | 12.94 A | 12.9 A | 0,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 53.2 V | 0,4% |
| Vmpp | 45.23 V | 45.43 V | 0,4% |
| Isc | 13.54 A | 13.58 A | 0,3% |
| Impp | 12.94 A | 13 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.6 V | 0,8% |
| Vmpp | 45.23 V | 44.83 V | 0,9% |
| Isc | 13.54 A | 13.46 A | 0,6% |
| Impp | 12.94 A | 12.83 A | 0,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.4 V | 1,1% |
| Vmpp | 45.23 V | 44.63 V | 1,3% |
| Isc | 13.54 A | 13.42 A | 0,9% |
| Impp | 12.94 A | 12.78 A | 1,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.8 V | 0,4% |
| Vmpp | 45.23 V | 44.1 V | 2,5% |
| Isc | 13.54 A | 14.36 A | 6,1% |
| Impp | 12.94 A | 13.5 A | 4,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 53.05 V | 0,1% |
| Vmpp | 45.23 V | 43.82 V | 3,1% |
| Isc | 13.54 A | 14.45 A | 6,7% |
| Impp | 12.94 A | 13.58 A | 4,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.48 V | 1,0% |
| Vmpp | 45.23 V | 43.61 V | 3,6% |
| Isc | 13.54 A | 13.67 A | 1,0% |
| Impp | 12.94 A | 13.42 A | 3,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.63 V | 0,7% |
| Vmpp | 45.23 V | 43.71 V | 3,4% |
| Isc | 13.54 A | 14.13 A | 4,4% |
| Impp | 12.94 A | 13.5 A | 4,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.63 V | 0,7% |
| Vmpp | 45.23 V | 43.71 V | 3,4% |
| Isc | 13.54 A | 14.13 A | 4,4% |
| Impp | 12.94 A | 13.5 A | 4,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
600 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.81 V | 0,4% |
| Vmpp | 45.23 V | 44.66 V | 1,3% |
| Isc | 13.54 A | 14.46 A | 6,8% |
| Impp | 12.94 A | 13.44 A | 3,9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.6 V | 0,8% |
| Vmpp | 45.23 V | 43.9 V | 2,9% |
| Isc | 13.54 A | 14.29 A | 5,5% |
| Impp | 12.94 A | 13.44 A | 3,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
600 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.81 V | 0,4% |
| Vmpp | 45.23 V | 44.66 V | 1,3% |
| Isc | 13.54 A | 14.46 A | 6,8% |
| Impp | 12.94 A | 13.44 A | 3,9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
53 V
Vmpp
45,23 V
Isc
13,54 A
Impp
12,94 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
585 W
Cells
144
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
35 mm
Gewicht
27,8 kg
Das Perlight Solar PLM-585H8N-144 ist ein 585 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| PLM-570H8N-144 | 570 W | 52.4 V | 13.42 A |
| PLM-575H8N-144 | 575 W | 52.6 V | 13.46 A |
| PLM-580H8N-144 | 580 W | 52.8 V | 13.5 A |
| PLM-590H8N-144 | 590 W | 53.2 V | 13.58 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 53 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Perlight Solar PLM-585H8N-144 übereinstimmen.