460 W TOPCon Solarmodul mit 96 Zellen. Voc 35,79 V · Isc 16,3 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
230 Module gefunden · 4109 Module ausgeschlossen
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.72 V | 0,2% |
| Vmpp | 30.28 V | 30.36 V | 0,3% |
| Isc | 16.3 A | 16.13 A | 1,0% |
| Impp | 15.22 A | 15.32 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
480 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.7 V | 0,3% |
| Vmpp | 30.28 V | 30.5 V | 0,7% |
| Isc | 16.3 A | 16.3 A | 0,0% |
| Impp | 15.22 A | 15.74 A | 3,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.6 V | 0,5% |
| Vmpp | 30.28 V | 30.4 V | 0,4% |
| Isc | 16.3 A | 16.26 A | 0,2% |
| Impp | 15.22 A | 15.63 A | 2,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.59 V | 0,6% |
| Vmpp | 30.28 V | 30.1 V | 0,6% |
| Isc | 16.3 A | 16.22 A | 0,5% |
| Impp | 15.22 A | 15.12 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.79 V | 0,0% |
| Vmpp | 30.28 V | 30.15 V | 0,4% |
| Isc | 16.3 A | 15.64 A | 4,0% |
| Impp | 15.22 A | 14.93 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.92 V | 0,4% |
| Vmpp | 30.28 V | 30.56 V | 0,9% |
| Isc | 16.3 A | 16.2 A | 0,6% |
| Impp | 15.22 A | 15.38 A | 1,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.85 V | 0,2% |
| Vmpp | 30.28 V | 30.08 V | 0,7% |
| Isc | 16.3 A | 16.13 A | 1,0% |
| Impp | 15.22 A | 15.13 A | 0,6% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.78 V | 0,0% |
| Vmpp | 30.28 V | 29.81 V | 1,6% |
| Isc | 16.3 A | 15.9 A | 2,5% |
| Impp | 15.22 A | 15.1 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.5 V | 0,8% |
| Vmpp | 30.28 V | 30.3 V | 0,1% |
| Isc | 16.3 A | 16.22 A | 0,5% |
| Impp | 15.22 A | 15.51 A | 1,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.8 V | 0,0% |
| Vmpp | 30.28 V | 30.4 V | 0,4% |
| Isc | 16.3 A | 15.58 A | 4,4% |
| Impp | 15.22 A | 14.64 A | 3,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.8 V | 0,0% |
| Vmpp | 30.28 V | 30.4 V | 0,4% |
| Isc | 16.3 A | 15.58 A | 4,4% |
| Impp | 15.22 A | 14.64 A | 3,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.79 V | 35.8 V | 0,0% |
| Vmpp | 30.28 V | 30.4 V | 0,4% |
| Isc | 16.3 A | 15.58 A | 4,4% |
| Impp | 15.22 A | 14.64 A | 3,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
35,79 V
Vmpp
30,28 V
Isc
16,3 A
Impp
15,22 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
460 W
Cells
96
Bifaciality
80%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
21,5 kg
Das Risen RSM96-11-460BNDG ist ein 460 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| RSM96-11-435BNDG | 435 W | 34.77 V | 15.9 A |
| RSM96-11-450BNDG | 450 W | 35.4 V | 16.14 A |
| RSM96-11-455BNDG | 455 W | 35.59 V | 16.22 A |
| RSM96-11-475BNDG | 475 W | 36.42 V | 16.52 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 35,79 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Risen RSM96-11-460BNDG übereinstimmen.