420 W TOPCon Solarmodul mit 108 Zellen. Voc 38,1 V · Isc 14,23 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
130 Module gefunden · 4209 Module ausgeschlossen
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.1 V | 0,0% |
| Vmpp | 32.01 V | 32.01 V | 0,0% |
| Isc | 14.23 A | 14.23 A | 0,0% |
| Impp | 13.12 A | 13.12 A | 0,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.21 V | 0,3% |
| Vmpp | 32.01 V | 32.15 V | 0,4% |
| Isc | 14.23 A | 14.3 A | 0,5% |
| Impp | 13.12 A | 13.22 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.21 V | 0,3% |
| Vmpp | 32.01 V | 32.15 V | 0,4% |
| Isc | 14.23 A | 14.3 A | 0,5% |
| Impp | 13.12 A | 13.22 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 37.99 V | 0,3% |
| Vmpp | 32.01 V | 31.75 V | 0,8% |
| Isc | 14.23 A | 14.16 A | 0,5% |
| Impp | 13.12 A | 13.07 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 37.99 V | 0,3% |
| Vmpp | 32.01 V | 31.75 V | 0,8% |
| Isc | 14.23 A | 14.16 A | 0,5% |
| Impp | 13.12 A | 13.07 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.08 V | 0,1% |
| Vmpp | 32.01 V | 31.79 V | 0,7% |
| Isc | 14.23 A | 14.09 A | 1,0% |
| Impp | 13.12 A | 13.21 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.23 V | 0,3% |
| Vmpp | 32.01 V | 32 V | 0,0% |
| Isc | 14.23 A | 14.16 A | 0,5% |
| Impp | 13.12 A | 13.28 A | 1,2% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.09 V | 0,0% |
| Vmpp | 32.01 V | 31.46 V | 1,7% |
| Isc | 14.23 A | 14.09 A | 1,0% |
| Impp | 13.12 A | 13.36 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.15 V | 0,1% |
| Vmpp | 32.01 V | 31.51 V | 1,6% |
| Isc | 14.23 A | 14.07 A | 1,1% |
| Impp | 13.12 A | 13.34 A | 1,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.11 V | 0,0% |
| Vmpp | 32.01 V | 31.51 V | 1,6% |
| Isc | 14.23 A | 14.07 A | 1,1% |
| Impp | 13.12 A | 13.33 A | 1,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.09 V | 0,0% |
| Vmpp | 32.01 V | 31.46 V | 1,7% |
| Isc | 14.23 A | 14.09 A | 1,0% |
| Impp | 13.12 A | 13.36 A | 1,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.1 V | 38.32 V | 0,6% |
| Vmpp | 32.01 V | 31.65 V | 1,1% |
| Isc | 14.23 A | 14.18 A | 0,4% |
| Impp | 13.12 A | 13.44 A | 2,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
38,1 V
Vmpp
32,01 V
Isc
14,23 A
Impp
13,12 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
420 W
Cells
108
Bifaciality
70%
Länge
1722 mm
Breite
1133 mm
Rahmentiefe
30 mm
Gewicht
23,5 kg
Das S-Energy SL65-54TEP-420R ist ein 420 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| SL65-54TEP-410R | 410 W | 37.8 V | 14.07 A |
| SL65-54TEP-415R | 415 W | 37.99 V | 14.16 A |
| SL65-54TEP-425R | 425 W | 38.21 V | 14.3 A |
| SL65-54TEP-430R | 430 W | 38.42 V | 14.36 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 38,1 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original S-Energy SL65-54TEP-420R übereinstimmen.