605 W TOPCon Solarmodul mit 156 Zellen. Voc 54,8 V · Isc 13,97 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
32 Module gefunden · 4307 Module ausgeschlossen
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.1 V | 0,5% |
| Vmpp | 45.8 V | 45.7 V | 0,2% |
| Isc | 13.97 A | 14.11 A | 1,0% |
| Impp | 13.22 A | 13.35 A | 1,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.3 V | 0,9% |
| Vmpp | 45.8 V | 45.9 V | 0,2% |
| Isc | 13.97 A | 14.16 A | 1,4% |
| Impp | 13.22 A | 13.4 A | 1,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.5 V | 1,3% |
| Vmpp | 45.8 V | 46.1 V | 0,7% |
| Isc | 13.97 A | 14.21 A | 1,7% |
| Impp | 13.22 A | 13.45 A | 1,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
605 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 54.43 V | 0,7% |
| Vmpp | 45.8 V | 45.81 V | 0,0% |
| Isc | 13.97 A | 14.11 A | 1,0% |
| Impp | 13.22 A | 13.22 A | 0,0% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0,040 %/°C |
605 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 54.43 V | 0,7% |
| Vmpp | 45.8 V | 45.81 V | 0,0% |
| Isc | 13.97 A | 14.11 A | 1,0% |
| Impp | 13.22 A | 13.22 A | 0,0% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0,040 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.74 V | 1,7% |
| Vmpp | 45.8 V | 46.09 V | 0,6% |
| Isc | 13.97 A | 14.27 A | 2,1% |
| Impp | 13.22 A | 13.56 A | 2,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
600 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 54.23 V | 1,0% |
| Vmpp | 45.8 V | 45.61 V | 0,4% |
| Isc | 13.97 A | 14.05 A | 0,6% |
| Impp | 13.22 A | 13.16 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0,040 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.7 V | 1,6% |
| Vmpp | 45.8 V | 46.3 V | 1,1% |
| Isc | 13.97 A | 14.26 A | 2,1% |
| Impp | 13.22 A | 13.5 A | 2,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
600 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 54.23 V | 1,0% |
| Vmpp | 45.8 V | 45.61 V | 0,4% |
| Isc | 13.97 A | 14.05 A | 0,6% |
| Impp | 13.22 A | 13.16 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0,040 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.6 V | 1,5% |
| Vmpp | 45.8 V | 46.8 V | 2,2% |
| Isc | 13.97 A | 14.08 A | 0,8% |
| Impp | 13.22 A | 13.25 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.6 V | 1,5% |
| Vmpp | 45.8 V | 46.8 V | 2,2% |
| Isc | 13.97 A | 14.08 A | 0,8% |
| Impp | 13.22 A | 13.25 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.8 V | 55.6 V | 1,5% |
| Vmpp | 45.8 V | 46.8 V | 2,2% |
| Isc | 13.97 A | 14.08 A | 0,8% |
| Impp | 13.22 A | 13.25 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
54,8 V
Vmpp
45,8 V
Isc
13,97 A
Impp
13,22 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
605 W
Cells
156
Bifaciality
70%
Länge
2465 mm
Breite
1133 mm
Rahmentiefe
30 mm
Gewicht
34,5 kg
Das S-Energy SL65-78TDP-605R ist ein 605 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 156), Voc nahe 54,8 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original S-Energy SL65-78TDP-605R übereinstimmen.