600 W TOPCon Solarmodul mit 144 Zellen. Voc 52 V · Isc 14,44 A · TcVoc -0,24%/°C.
Wählen Sie das Modul, das ersetzt werden soll
133 Module gefunden · 4206 Module ausgeschlossen
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.94 V | 0,1% |
| Vmpp | 43.4 V | 43.13 V | 0,6% |
| Isc | 14.44 A | 14.64 A | 1,4% |
| Impp | 13.83 A | 13.91 A | 0,6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.07 V | 0,1% |
| Vmpp | 43.4 V | 43.24 V | 0,4% |
| Isc | 14.44 A | 14.72 A | 1,9% |
| Impp | 13.83 A | 13.99 A | 1,2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.02 V | 0,0% |
| Vmpp | 43.4 V | 43.41 V | 0,0% |
| Isc | 14.44 A | 14.36 A | 0,6% |
| Impp | 13.83 A | 13.59 A | 1,7% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.98 V | 0,0% |
| Vmpp | 43.4 V | 43.35 V | 0,1% |
| Isc | 14.44 A | 14.3 A | 1,0% |
| Impp | 13.83 A | 13.62 A | 1,5% |
| TcVoc | -0.24 %/°C | -0.26 %/°C | ±0,020 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.81 V | 0,4% |
| Vmpp | 43.4 V | 43.02 V | 0,9% |
| Isc | 14.44 A | 14.56 A | 0,8% |
| Impp | 13.83 A | 13.83 A | 0,0% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.95 V | 0,1% |
| Vmpp | 43.4 V | 43.67 V | 0,6% |
| Isc | 14.44 A | 14.18 A | 1,8% |
| Impp | 13.83 A | 13.51 A | 2,3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.6 V | 0,8% |
| Vmpp | 43.4 V | 43.4 V | 0,0% |
| Isc | 14.44 A | 14.34 A | 0,7% |
| Impp | 13.83 A | 13.59 A | 1,7% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 52.11 V | 0,2% |
| Vmpp | 43.4 V | 43.04 V | 0,8% |
| Isc | 14.44 A | 14.34 A | 0,7% |
| Impp | 13.83 A | 13.48 A | 2,5% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52 V | 51.95 V | 0,1% |
| Vmpp | 43.4 V | 43.76 V | 0,8% |
| Isc | 14.44 A | 14.62 A | 1,2% |
| Impp | 13.83 A | 13.83 A | 0,0% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.28 %/°C | ±0,020 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
52 V
Vmpp
43,4 V
Isc
14,44 A
Impp
13,83 A
TcVoc
-0,24 %/°C
TcPmax
-0,3 %/°C
Pmax
600 W
Cells
144
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
27,7 kg
Das Tensite EM600-PH 30mm ist ein 600 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 52 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,24%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Tensite EM600-PH 30mm übereinstimmen.