570 W TOPCon Solarmodul mit 144 Zellen. Voc 51,24 V · Isc 14,21 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
216 Module gefunden · 4123 Module ausgeschlossen
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.24 V | 0,0% |
| Vmpp | 42.88 V | 42.88 V | 0,0% |
| Isc | 14.21 A | 14.21 A | 0,0% |
| Impp | 13.29 A | 13.29 A | 0,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.15 V | 0,2% |
| Vmpp | 42.88 V | 42.91 V | 0,1% |
| Isc | 14.21 A | 14.39 A | 1,3% |
| Impp | 13.29 A | 13.4 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.04 V | 0,4% |
| Vmpp | 42.88 V | 42.68 V | 0,5% |
| Isc | 14.21 A | 14.17 A | 0,3% |
| Impp | 13.29 A | 13.24 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.44 V | 0,4% |
| Vmpp | 42.88 V | 43.08 V | 0,5% |
| Isc | 14.21 A | 14.25 A | 0,3% |
| Impp | 13.29 A | 13.35 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.04 V | 0,4% |
| Vmpp | 42.88 V | 42.68 V | 0,5% |
| Isc | 14.21 A | 14.17 A | 0,3% |
| Impp | 13.29 A | 13.24 A | 0,4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.44 V | 0,4% |
| Vmpp | 42.88 V | 43.08 V | 0,5% |
| Isc | 14.21 A | 14.25 A | 0,3% |
| Impp | 13.29 A | 13.35 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.33 V | 0,2% |
| Vmpp | 42.88 V | 42.6 V | 0,7% |
| Isc | 14.21 A | 14 A | 1,5% |
| Impp | 13.29 A | 13.5 A | 1,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.27 V | 0,1% |
| Vmpp | 42.88 V | 42.44 V | 1,0% |
| Isc | 14.21 A | 14.31 A | 0,7% |
| Impp | 13.29 A | 13.55 A | 2,0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.17 V | 0,1% |
| Vmpp | 42.88 V | 42.27 V | 1,4% |
| Isc | 14.21 A | 14.1 A | 0,8% |
| Impp | 13.29 A | 13.37 A | 0,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.17 V | 0,1% |
| Vmpp | 42.88 V | 42.27 V | 1,4% |
| Isc | 14.21 A | 14.1 A | 0,8% |
| Impp | 13.29 A | 13.37 A | 0,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.18 V | 0,1% |
| Vmpp | 42.88 V | 42.45 V | 1,0% |
| Isc | 14.21 A | 13.92 A | 2,0% |
| Impp | 13.29 A | 13.43 A | 1,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.24 V | 51.42 V | 0,4% |
| Vmpp | 42.88 V | 42.71 V | 0,4% |
| Isc | 14.21 A | 14.37 A | 1,1% |
| Impp | 13.29 A | 13.58 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
51,24 V
Vmpp
42,88 V
Isc
14,21 A
Impp
13,29 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
570 W
Cells
144
Bifaciality
80%
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32,7 kg
Das Tongwei TWMND-72HD570 ist ein 570 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| TWMND-72HD555 | 555 W | 50.64 V | 14.09 A |
| TWMND-72HD560 | 560 W | 50.84 V | 14.13 A |
| TWMND-72HD565 | 565 W | 51.04 V | 14.17 A |
| TWMND-72HD575 | 575 W | 51.44 V | 14.25 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 51,24 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Tongwei TWMND-72HD570 übereinstimmen.