580 W TOPCon Solarmodul mit 144 Zellen. Voc 52,52 V · Isc 13,95 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
217 Module gefunden · 4122 Module ausgeschlossen
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.5 V | 0,0% |
| Vmpp | 44.02 V | 43.88 V | 0,3% |
| Isc | 13.95 A | 13.95 A | 0,0% |
| Impp | 13.18 A | 13.22 A | 0,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.5 V | 0,0% |
| Vmpp | 44.02 V | 43.85 V | 0,4% |
| Isc | 13.95 A | 13.99 A | 0,3% |
| Impp | 13.18 A | 13.24 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.45 V | 0,1% |
| Vmpp | 44.02 V | 44.08 V | 0,1% |
| Isc | 13.95 A | 14.08 A | 0,9% |
| Impp | 13.18 A | 13.27 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.5 V | 0,0% |
| Vmpp | 44.02 V | 44.1 V | 0,2% |
| Isc | 13.95 A | 13.9 A | 0,4% |
| Impp | 13.18 A | 13.27 A | 0,7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0,010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.7 V | 0,3% |
| Vmpp | 44.02 V | 44.02 V | 0,0% |
| Isc | 13.95 A | 14.01 A | 0,4% |
| Impp | 13.18 A | 13.29 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.3 V | 0,4% |
| Vmpp | 44.02 V | 43.95 V | 0,2% |
| Isc | 13.95 A | 13.98 A | 0,2% |
| Impp | 13.18 A | 13.2 A | 0,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.7 V | 0,3% |
| Vmpp | 44.02 V | 44.04 V | 0,0% |
| Isc | 13.95 A | 14.05 A | 0,7% |
| Impp | 13.18 A | 13.3 A | 0,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.6 V | 0,2% |
| Vmpp | 44.02 V | 44.2 V | 0,4% |
| Isc | 13.95 A | 14.18 A | 1,6% |
| Impp | 13.18 A | 13.35 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.32 V | 0,4% |
| Vmpp | 44.02 V | 43.85 V | 0,4% |
| Isc | 13.95 A | 13.89 A | 0,4% |
| Impp | 13.18 A | 13.11 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.72 V | 0,4% |
| Vmpp | 44.02 V | 44.17 V | 0,3% |
| Isc | 13.95 A | 14.02 A | 0,5% |
| Impp | 13.18 A | 13.24 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.37 V | 0,3% |
| Vmpp | 44.02 V | 44 V | 0,0% |
| Isc | 13.95 A | 14.18 A | 1,6% |
| Impp | 13.18 A | 13.32 A | 1,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.52 V | 52.37 V | 0,3% |
| Vmpp | 44.02 V | 44.43 V | 0,9% |
| Isc | 13.95 A | 13.94 A | 0,1% |
| Impp | 13.18 A | 13.28 A | 0,8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0,000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
52,52 V
Vmpp
44,02 V
Isc
13,95 A
Impp
13,18 A
TcVoc
-0,25 %/°C
TcPmax
-0,29 %/°C
Pmax
580 W
Cells
144
Bifaciality
80%
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
30,6 kg
Das Ulica Solar UL-580M-144ADGN ist ein 580 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| UL-575M-144ADGN | 575 W | 52.32 V | 13.89 A |
| UL-585M-144ADGN | 585 W | 52.72 V | 14.02 A |
| UL-590M-144ADGN | 590 W | 52.92 V | 14.06 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 52,52 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Ulica Solar UL-580M-144ADGN übereinstimmen.