430 W PERC Solarmodul mit 144 Zellen. Voc 49,39 V · Isc 11,19 A · TcVoc -0,285%/°C.
Wählen Sie das Modul, das ersetzt werden soll
32 Module gefunden · 4307 Module ausgeschlossen
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.59 V | 0,4% |
| Vmpp | 41.01 V | 41.21 V | 0,5% |
| Isc | 11.19 A | 11.25 A | 0,5% |
| Impp | 10.49 A | 10.56 A | 0,7% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.19 V | 0,4% |
| Vmpp | 41.01 V | 40.81 V | 0,5% |
| Isc | 11.19 A | 11.11 A | 0,7% |
| Impp | 10.49 A | 10.42 A | 0,7% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.34 V | 0,1% |
| Vmpp | 41.01 V | 41.44 V | 1,0% |
| Isc | 11.19 A | 11.34 A | 1,3% |
| Impp | 10.49 A | 10.74 A | 2,4% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.5 V | 0,2% |
| Vmpp | 41.01 V | 40.6 V | 1,0% |
| Isc | 11.19 A | 11.19 A | 0,0% |
| Impp | 10.49 A | 10.6 A | 1,0% |
| TcVoc | -0.285 %/°C | -0.29 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.69 V | 0,6% |
| Vmpp | 41.01 V | 41.41 V | 1,0% |
| Isc | 11.19 A | 11.34 A | 1,3% |
| Impp | 10.49 A | 10.63 A | 1,3% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.7 V | 0,6% |
| Vmpp | 41.01 V | 40.8 V | 0,5% |
| Isc | 11.19 A | 11.26 A | 0,6% |
| Impp | 10.49 A | 10.67 A | 1,7% |
| TcVoc | -0.285 %/°C | -0.29 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49 V | 0,8% |
| Vmpp | 41.01 V | 41.16 V | 0,4% |
| Isc | 11.19 A | 11.3 A | 1,0% |
| Impp | 10.49 A | 10.7 A | 2,0% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.01 V | 0,8% |
| Vmpp | 41.01 V | 40.61 V | 1,0% |
| Isc | 11.19 A | 11.04 A | 1,3% |
| Impp | 10.49 A | 10.35 A | 1,3% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0,000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.7 V | 0,6% |
| Vmpp | 41.01 V | 40.8 V | 0,5% |
| Isc | 11.19 A | 11.26 A | 0,6% |
| Impp | 10.49 A | 10.67 A | 1,7% |
| TcVoc | -0.285 %/°C | -0.29 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.9 V | 1,0% |
| Vmpp | 41.01 V | 41 V | 0,0% |
| Isc | 11.19 A | 11.33 A | 1,3% |
| Impp | 10.49 A | 10.74 A | 2,4% |
| TcVoc | -0.285 %/°C | -0.29 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.9 V | 1,0% |
| Vmpp | 41.01 V | 41 V | 0,0% |
| Isc | 11.19 A | 11.33 A | 1,3% |
| Impp | 10.49 A | 10.74 A | 2,4% |
| TcVoc | -0.285 %/°C | -0.29 %/°C | ±0,005 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.39 V | 49.68 V | 0,6% |
| Vmpp | 41.01 V | 41.73 V | 1,8% |
| Isc | 11.19 A | 11.39 A | 1,8% |
| Impp | 10.49 A | 10.79 A | 2,9% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0,000 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
49,39 V
Vmpp
41,01 V
Isc
11,19 A
Impp
10,49 A
TcVoc
-0,285 %/°C
TcPmax
-0,35 %/°C
Pmax
430 W
Cells
144
Länge
2113 mm
Breite
1052 mm
Rahmentiefe
35 mm
Gewicht
23 kg
Das Waaree Energies WSMD-430 ist ein 430 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 49,39 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,285%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Waaree Energies WSMD-430 übereinstimmen.