Pannello solare PERC da 440 W con 144 celle. Voc 49 V · Isc 11.3 A · TcVoc -0.285%/°C.
Scegli il pannello da sostituire
30 pannelli trovati · 3670 pannelli esclusi
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.34 V | 0.7% |
| Vmpp | 41.16 V | 41.44 V | 0.7% |
| Isc | 11.3 A | 11.34 A | 0.4% |
| Impp | 10.7 A | 10.74 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.05 V | 0.1% |
| Vmpp | 41.16 V | 41.32 V | 0.4% |
| Isc | 11.3 A | 11.37 A | 0.6% |
| Impp | 10.7 A | 10.89 A | 1.8% |
| TcVoc | -0.285 %/°C | -0.27 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49 V | 0.0% |
| Vmpp | 41.16 V | 41.2 V | 0.1% |
| Isc | 11.3 A | 11.54 A | 2.1% |
| Impp | 10.7 A | 10.81 A | 1.0% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.01 V | 0.0% |
| Vmpp | 41.16 V | 40.61 V | 1.3% |
| Isc | 11.3 A | 11.04 A | 2.3% |
| Impp | 10.7 A | 10.35 A | 3.3% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.19 V | 0.4% |
| Vmpp | 41.16 V | 40.81 V | 0.9% |
| Isc | 11.3 A | 11.11 A | 1.7% |
| Impp | 10.7 A | 10.42 A | 2.6% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 48.8 V | 0.4% |
| Vmpp | 41.16 V | 41.05 V | 0.3% |
| Isc | 11.3 A | 11.3 A | 0.0% |
| Impp | 10.7 A | 10.84 A | 1.3% |
| TcVoc | -0.285 %/°C | -0.27 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.39 V | 0.8% |
| Vmpp | 41.16 V | 41.01 V | 0.4% |
| Isc | 11.3 A | 11.19 A | 1.0% |
| Impp | 10.7 A | 10.49 A | 2.0% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 48.8 V | 0.4% |
| Vmpp | 41.16 V | 41 V | 0.4% |
| Isc | 11.3 A | 11.47 A | 1.5% |
| Impp | 10.7 A | 10.74 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.59 V | 1.2% |
| Vmpp | 41.16 V | 41.21 V | 0.1% |
| Isc | 11.3 A | 11.25 A | 0.4% |
| Impp | 10.7 A | 10.56 A | 1.3% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.2 V | 0.4% |
| Vmpp | 41.16 V | 41.4 V | 0.6% |
| Isc | 11.3 A | 11.61 A | 2.7% |
| Impp | 10.7 A | 10.87 A | 1.6% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.69 V | 1.4% |
| Vmpp | 41.16 V | 41.41 V | 0.6% |
| Isc | 11.3 A | 11.34 A | 0.4% |
| Impp | 10.7 A | 10.63 A | 0.7% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.68 V | 1.4% |
| Vmpp | 41.16 V | 41.73 V | 1.4% |
| Isc | 11.3 A | 11.39 A | 0.8% |
| Impp | 10.7 A | 10.79 A | 0.8% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
Calcolatore di compatibilità della stringa
Verifica che il sostituto funzioni con il tuo inverter
Ricerca pannelli
Tutti i pannelli compatibili con un inverter
Hai già i pannelli?
Trova un inverter che si adatti al tuo impianto — range MPPT e rapporto DC/AC verificati.
Come funziona l'algoritmo
Come i pannelli vengono valutati e abbinati
Voc
49 V
Vmpp
41.16 V
Isc
11.3 A
Impp
10.7 A
TcVoc
-0.285 %/°C
TcPmax
-0.36 %/°C
Pmax
440 W
Cells
144
Lunghezza
2094 mm
Larghezza
1038 mm
Spessore
35 mm
Peso
23.5 kg
Il Luxor Solar LX-440M/166-144+ SW HC è un pannello solare da 440 W. Per trovare un sostituto compatibile è necessario che le caratteristiche elettriche — in particolare Voc, Vmpp, Isc e i coefficienti di temperatura — corrispondano per garantire un funzionamento sicuro nella stessa stringa.
Usa il modulo sopra per trovare pannelli con specifiche compatibili. Poi verifica la sostituzione nel Calcolatore di Compatibilità delle Stringhe con il tuo inverter.
| Modello | Potenza | Voc | Isc |
|---|---|---|---|
| 445 W | 49.34 V | 11.34 A | |
| 450 W | 49.68 V | 11.39 A | |
| 455 W | 50.03 V | 11.44 A | |
| 460 W | 50.38 V | 11.49 A |
Le specifiche più critiche sono: numero di celle (esattamente 144), Voc vicino a 49 V (±5%) e coefficiente di temperatura TcVoc vicino a -0.285%/°C. Se il Voc differisce significativamente, la tensione della stringa alle temperature estreme può uscire dalla faixa MPPT dell'inverter. Il trovatore di sostituzioni prescreena automaticamente i candidati secondo questi criteri.
Un pannello di potenza superiore di solito ha un Vmpp o Isc più alto, il che può influenzare la tensione e la corrente della stringa. Piccoli aumenti (fino al 10–15%) sono generalmente sicuri se le altre specifiche coincidono. Il trovatore mostra un punteggio di compatibilità — 'Corrispondenza esatta' significa specifiche molto vicine. Verifica sempre la sostituzione nel Calcolatore di Compatibilità Stringa con il tuo inverter prima dell'installazione.
Se il sostituto ha un Voc o Vmpp significativamente diverso, la tensione della stringa può uscire dal range MPPT dell'inverter, riducendo la produzione di energia o causando guasti. Questo effetto è amplificato alle temperature estreme. Il trovatore lo tiene in conto automaticamente — valuta i candidati in base a quanto le specifiche elettriche si avvicinano al Luxor Solar LX-440M/166-144+ SW HC originale.