Painel solar PERC de 450 W com 144 células. Voc 49.05 V · Isc 11.37 A · TcVoc -0.27%/°C.
Escolha o painel que precisa de substituir
26 painéis encontrados · 3674 painéis excluídos
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 48.8 V | 0.5% |
| Vmpp | 41.32 V | 41.05 V | 0.7% |
| Isc | 11.37 A | 11.3 A | 0.6% |
| Impp | 10.89 A | 10.84 A | 0.5% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.35 V | 0.6% |
| Vmpp | 41.32 V | 41.51 V | 0.5% |
| Isc | 11.37 A | 11.44 A | 0.6% |
| Impp | 10.89 A | 10.96 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49 V | 0.1% |
| Vmpp | 41.32 V | 41.16 V | 0.4% |
| Isc | 11.37 A | 11.3 A | 0.6% |
| Impp | 10.89 A | 10.7 A | 1.7% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.34 V | 0.6% |
| Vmpp | 41.32 V | 41.44 V | 0.3% |
| Isc | 11.37 A | 11.34 A | 0.3% |
| Impp | 10.89 A | 10.74 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49 V | 0.1% |
| Vmpp | 41.32 V | 41.2 V | 0.3% |
| Isc | 11.37 A | 11.54 A | 1.5% |
| Impp | 10.89 A | 10.81 A | 0.7% |
| TcVoc | -0.27 %/°C | -0.304 %/°C | ±0.034 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.39 V | 0.7% |
| Vmpp | 41.32 V | 41.01 V | 0.8% |
| Isc | 11.37 A | 11.19 A | 1.6% |
| Impp | 10.89 A | 10.49 A | 3.7% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.2 V | 0.3% |
| Vmpp | 41.32 V | 41.4 V | 0.2% |
| Isc | 11.37 A | 11.61 A | 2.1% |
| Impp | 10.89 A | 10.87 A | 0.2% |
| TcVoc | -0.27 %/°C | -0.304 %/°C | ±0.034 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.59 V | 1.1% |
| Vmpp | 41.32 V | 41.21 V | 0.3% |
| Isc | 11.37 A | 11.25 A | 1.1% |
| Impp | 10.89 A | 10.56 A | 3.0% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.69 V | 1.3% |
| Vmpp | 41.32 V | 41.41 V | 0.2% |
| Isc | 11.37 A | 11.34 A | 0.3% |
| Impp | 10.89 A | 10.63 A | 2.4% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 48.8 V | 0.5% |
| Vmpp | 41.32 V | 41 V | 0.8% |
| Isc | 11.37 A | 11.47 A | 0.9% |
| Impp | 10.89 A | 10.74 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.304 %/°C | ±0.034 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.68 V | 1.3% |
| Vmpp | 41.32 V | 41.73 V | 1.0% |
| Isc | 11.37 A | 11.39 A | 0.2% |
| Impp | 10.89 A | 10.79 A | 0.9% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.36 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.05 V | 49.89 V | 1.7% |
| Vmpp | 41.32 V | 41.61 V | 0.7% |
| Isc | 11.37 A | 11.41 A | 0.4% |
| Impp | 10.89 A | 10.7 A | 1.7% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
49.05 V
Vmpp
41.32 V
Isc
11.37 A
Impp
10.89 A
TcVoc
-0.27 %/°C
TcPmax
-0.35 %/°C
Pmax
450 W
Cells
144
Comprimento
2094 mm
Largura
1038 mm
Espessura
35 mm
Peso
23 kg
O Astronergy CHSM72M-HC-450 é um painel solar de 450 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 445 W | 48.8 V | 11.3 A | |
| 455 W | 49.35 V | 11.44 A |
As especificações mais críticas são: número de células (exatamente 144), Voc próximo a 49.05 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.27%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Astronergy CHSM72M-HC-450 original.