Painel solar TOPCon de 440 W com 96 células. Voc 34.74 V · Isc 15.9 A · TcVoc -0.25%/°C.
Escolha o painel que precisa de substituir
17 painéis encontrados · 3683 painéis excluídos
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.7 V | 0.1% |
| Vmpp | 29.65 V | 29.06 V | 2.0% |
| Isc | 15.9 A | 15.95 A | 0.3% |
| Impp | 14.84 A | 14.97 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.84 V | 0.3% |
| Vmpp | 29.65 V | 29.2 V | 1.5% |
| Isc | 15.9 A | 16 A | 0.6% |
| Impp | 14.84 A | 15.07 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.49 V | 0.7% |
| Vmpp | 29.65 V | 29.43 V | 0.7% |
| Isc | 15.9 A | 15.84 A | 0.4% |
| Impp | 14.84 A | 14.78 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.97 V | 0.7% |
| Vmpp | 29.65 V | 29.87 V | 0.7% |
| Isc | 15.9 A | 15.96 A | 0.4% |
| Impp | 14.84 A | 14.9 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.11 V | 1.1% |
| Vmpp | 29.65 V | 29.83 V | 0.6% |
| Isc | 15.9 A | 16.01 A | 0.7% |
| Impp | 14.84 A | 14.92 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.21 V | 1.4% |
| Vmpp | 29.65 V | 30.08 V | 1.5% |
| Isc | 15.9 A | 16.02 A | 0.8% |
| Impp | 14.84 A | 14.96 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.76 V | 2.9% |
| Vmpp | 29.65 V | 29.54 V | 0.4% |
| Isc | 15.9 A | 15.94 A | 0.3% |
| Impp | 14.84 A | 15.08 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.7 V | 2.8% |
| Vmpp | 29.65 V | 29.77 V | 0.4% |
| Isc | 15.9 A | 15.56 A | 2.1% |
| Impp | 14.84 A | 14.78 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.3 V | 1.6% |
| Vmpp | 29.65 V | 30.02 V | 1.2% |
| Isc | 15.9 A | 16.08 A | 1.1% |
| Impp | 14.84 A | 14.99 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.77 V | 0.1% |
| Vmpp | 29.65 V | 29.31 V | 1.1% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.84 A | 14.85 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0.030 %/°C |
| TcPmax | -0.29 %/°C | -0.24 %/°C | ±0.050 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 35.45 V | 2.0% |
| Vmpp | 29.65 V | 30.29 V | 2.2% |
| Isc | 15.9 A | 16.08 A | 1.1% |
| Impp | 14.84 A | 15.02 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.74 V | 34.98 V | 0.7% |
| Vmpp | 29.65 V | 29.5 V | 0.5% |
| Isc | 15.9 A | 15.98 A | 0.5% |
| Impp | 14.84 A | 14.92 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.22 %/°C | ±0.030 %/°C |
| TcPmax | -0.29 %/°C | -0.24 %/°C | ±0.050 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
34.74 V
Vmpp
29.65 V
Isc
15.9 A
Impp
14.84 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
440 W
Cells
96
Comprimento
1762 mm
Largura
1134 mm
Espessura
30 mm
Peso
24 kg
O Luxen Solar LNDX-440ND é um painel solar de 440 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 435 W | 34.49 V | 15.84 A | |
| 445 W | 34.97 V | 15.96 A | |
| 450 W | 35.21 V | 16.02 A | |
| 455 W | 35.45 V | 16.08 A |
As especificações mais críticas são: número de células (exatamente 96), Voc próximo a 34.74 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.25%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Luxen Solar LNDX-440ND original.