Painel solar PERC de 660 W com 132 células. Voc 45.06 V · Isc 18.42 A · TcVoc -0.285%/°C.
Escolha o painel que precisa de substituir
21 painéis encontrados · 3679 painéis excluídos
655 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 44.76 V | 0.7% |
| Vmpp | 37.85 V | 37.6 V | 0.7% |
| Isc | 18.42 A | 18.41 A | 0.1% |
| Impp | 17.44 A | 17.43 A | 0.1% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
665 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.36 V | 0.7% |
| Vmpp | 37.85 V | 38.11 V | 0.7% |
| Isc | 18.42 A | 18.44 A | 0.1% |
| Impp | 17.44 A | 17.46 A | 0.1% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
650 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45 V | 0.1% |
| Vmpp | 37.85 V | 37.9 V | 0.1% |
| Isc | 18.42 A | 18.39 A | 0.2% |
| Impp | 17.44 A | 17.16 A | 1.6% |
| TcVoc | -0.285 %/°C | -0.26 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
650 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.58 V | 1.2% |
| Vmpp | 37.85 V | 37.61 V | 0.6% |
| Isc | 18.42 A | 18.16 A | 1.4% |
| Impp | 17.44 A | 17.28 A | 0.9% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
650 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 44.46 V | 1.3% |
| Vmpp | 37.85 V | 37.35 V | 1.3% |
| Isc | 18.42 A | 18.38 A | 0.2% |
| Impp | 17.44 A | 17.41 A | 0.2% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
670 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.67 V | 1.4% |
| Vmpp | 37.85 V | 38.36 V | 1.3% |
| Isc | 18.42 A | 18.45 A | 0.2% |
| Impp | 17.44 A | 17.47 A | 0.2% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
655 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.2 V | 0.3% |
| Vmpp | 37.85 V | 38.1 V | 0.7% |
| Isc | 18.42 A | 18.43 A | 0.1% |
| Impp | 17.44 A | 17.2 A | 1.4% |
| TcVoc | -0.285 %/°C | -0.26 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
655 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.78 V | 1.6% |
| Vmpp | 37.85 V | 37.81 V | 0.1% |
| Isc | 18.42 A | 18.21 A | 1.1% |
| Impp | 17.44 A | 17.32 A | 0.7% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
645 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 44.8 V | 0.6% |
| Vmpp | 37.85 V | 37.7 V | 0.4% |
| Isc | 18.42 A | 18.35 A | 0.4% |
| Impp | 17.44 A | 17.11 A | 1.9% |
| TcVoc | -0.285 %/°C | -0.26 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
645 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.1 V | 0.1% |
| Vmpp | 37.85 V | 37.3 V | 1.5% |
| Isc | 18.42 A | 18.31 A | 0.6% |
| Impp | 17.44 A | 17.29 A | 0.9% |
| TcVoc | -0.285 %/°C | -0.25 %/°C | ±0.035 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
660 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.98 V | 2.0% |
| Vmpp | 37.85 V | 38.01 V | 0.4% |
| Isc | 18.42 A | 18.26 A | 0.9% |
| Impp | 17.44 A | 17.36 A | 0.5% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
650 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.06 V | 45.3 V | 0.5% |
| Vmpp | 37.85 V | 37.5 V | 0.9% |
| Isc | 18.42 A | 18.36 A | 0.3% |
| Impp | 17.44 A | 17.34 A | 0.6% |
| TcVoc | -0.285 %/°C | -0.25 %/°C | ±0.035 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
45.06 V
Vmpp
37.85 V
Isc
18.42 A
Impp
17.44 A
TcVoc
-0.285 %/°C
TcPmax
-0.36 %/°C
Pmax
660 W
Cells
132
Comprimento
2384 mm
Largura
1303 mm
Espessura
35 mm
Peso
34 kg
O Luxor Solar LX-660M/210-132+ SW HC é um painel solar de 660 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 650 W | 44.46 V | 18.38 A | |
| 655 W | 44.76 V | 18.41 A | |
| 665 W | 45.36 V | 18.44 A | |
| 670 W | 45.67 V | 18.45 A |
As especificações mais críticas são: número de células (exatamente 132), Voc próximo a 45.06 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.285%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Luxor Solar LX-660M/210-132+ SW HC original.