Painel solar TOPCon de 450 W com 108 células. Voc 38.7 V · Isc 14.73 A · TcVoc -0.23%/°C.
Escolha o painel que precisa de substituir
106 painéis encontrados · 3594 painéis excluídos
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.5 V | 0.5% |
| Vmpp | 32.2 V | 32 V | 0.6% |
| Isc | 14.73 A | 14.66 A | 0.5% |
| Impp | 13.98 A | 13.91 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.9 V | 0.5% |
| Vmpp | 32.2 V | 32.4 V | 0.6% |
| Isc | 14.73 A | 14.8 A | 0.5% |
| Impp | 13.98 A | 14.05 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.7 V | 0.0% |
| Vmpp | 32.2 V | 32.7 V | 1.6% |
| Isc | 14.73 A | 14.26 A | 3.2% |
| Impp | 13.98 A | 13.46 A | 3.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.9 V | 0.5% |
| Vmpp | 32.2 V | 33 V | 2.5% |
| Isc | 14.73 A | 14.68 A | 0.3% |
| Impp | 13.98 A | 13.79 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.5 V | 0.5% |
| Vmpp | 32.2 V | 32.5 V | 0.9% |
| Isc | 14.73 A | 14.19 A | 3.7% |
| Impp | 13.98 A | 13.39 A | 4.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.3 V | 1.0% |
| Vmpp | 32.2 V | 31.8 V | 1.2% |
| Isc | 14.73 A | 14.59 A | 1.0% |
| Impp | 13.98 A | 13.84 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 39.1 V | 1.0% |
| Vmpp | 32.2 V | 32.6 V | 1.2% |
| Isc | 14.73 A | 14.87 A | 1.0% |
| Impp | 13.98 A | 14.12 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.9 V | 0.5% |
| Vmpp | 32.2 V | 32.9 V | 2.2% |
| Isc | 14.73 A | 14.33 A | 2.7% |
| Impp | 13.98 A | 13.53 A | 3.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.67 V | 0.1% |
| Vmpp | 32.2 V | 32.07 V | 0.4% |
| Isc | 14.73 A | 14.31 A | 2.9% |
| Impp | 13.98 A | 13.57 A | 2.9% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.3 %/°C | ±0.020 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.3 V | 1.0% |
| Vmpp | 32.2 V | 32.3 V | 0.3% |
| Isc | 14.73 A | 14.12 A | 4.1% |
| Impp | 13.98 A | 13.32 A | 4.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 38.7 V | 0.0% |
| Vmpp | 32.2 V | 32.8 V | 1.9% |
| Isc | 14.73 A | 14.48 A | 1.7% |
| Impp | 13.98 A | 13.59 A | 2.8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.7 V | 39.08 V | 1.0% |
| Vmpp | 32.2 V | 33.15 V | 3.0% |
| Isc | 14.73 A | 14.78 A | 0.3% |
| Impp | 13.98 A | 13.88 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
38.7 V
Vmpp
32.2 V
Isc
14.73 A
Impp
13.98 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
450 W
Cells
108
Comprimento
1762 mm
Largura
1134 mm
Espessura
30 mm
Peso
22 kg
O RECOM RCM-450-7NG é um painel solar de 450 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 440 W | 38.3 V | 14.59 A | |
| 445 W | 38.5 V | 14.66 A | |
| 455 W | 38.9 V | 14.8 A | |
| 460 W | 39.1 V | 14.87 A |
As especificações mais críticas são: número de células (exatamente 108), Voc próximo a 38.7 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.23%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o RECOM RCM-450-7NG original.