Painel solar TOPCon de 470 W com 96 células. Voc 36.6 V · Isc 15.9 A · TcVoc -0.25%/°C.
Escolha o painel que precisa de substituir
64 painéis encontrados · 3447 painéis excluídos
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.6 V | 0.0% |
| Vmpp | 31.5 V | 31.5 V | 0.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 15 A | 15 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.6 V | 0.0% |
| Vmpp | 31.5 V | 31.5 V | 0.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 15 A | 15 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.6 V | 0.0% |
| Vmpp | 31.5 V | 31.47 V | 0.1% |
| Isc | 15.9 A | 15.93 A | 0.2% |
| Impp | 15 A | 14.95 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.5 V | 0.3% |
| Vmpp | 31.5 V | 31.2 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 15 A | 14.9 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.5 V | 0.3% |
| Vmpp | 31.5 V | 31.2 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 15 A | 14.9 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.5 V | 0.3% |
| Vmpp | 31.5 V | 31.2 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 15 A | 14.9 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.74 V | 0.4% |
| Vmpp | 31.5 V | 31.68 V | 0.6% |
| Isc | 15.9 A | 15.98 A | 0.5% |
| Impp | 15 A | 14.99 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.59 V | 0.0% |
| Vmpp | 31.5 V | 30.97 V | 1.7% |
| Isc | 15.9 A | 15.93 A | 0.2% |
| Impp | 15 A | 15.18 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.57 V | 0.1% |
| Vmpp | 31.5 V | 30.94 V | 1.8% |
| Isc | 15.9 A | 15.81 A | 0.6% |
| Impp | 15 A | 15.03 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.74 V | 0.4% |
| Vmpp | 31.5 V | 31.17 V | 1.0% |
| Isc | 15.9 A | 15.86 A | 0.3% |
| Impp | 15 A | 15.08 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.46 V | 0.4% |
| Vmpp | 31.5 V | 31.21 V | 0.9% |
| Isc | 15.9 A | 15.88 A | 0.1% |
| Impp | 15 A | 14.91 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.6 V | 36.56 V | 0.1% |
| Vmpp | 31.5 V | 30.97 V | 1.7% |
| Isc | 15.9 A | 16.03 A | 0.8% |
| Impp | 15 A | 15.18 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
36.6 V
Vmpp
31.5 V
Isc
15.9 A
Impp
15 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
470 W
Cells
96
Comprimento
1762 mm
Largura
1134 mm
Espessura
35 mm
Peso
24.8 kg
O Solarwatt Panel vision M 5.5 style 470 Wp é um painel solar de 470 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 460 W | 36.3 V | 15.8 A | |
| 465 W | 36.5 V | 15.9 A |
As especificações mais críticas são: número de células (exatamente 96), Voc próximo a 36.6 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.25%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Solarwatt Panel vision M 5.5 style 470 Wp original.