Painel solar TOPCon de 575 W com 144 células. Voc 52.18 V · Isc 13.58 A · TcVoc -0.25%/°C.
Escolha o painel que precisa de substituir
79 painéis encontrados · 3351 painéis excluídos
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.15 V | 0.1% |
| Vmpp | 43.22 V | 43.17 V | 0.1% |
| Isc | 13.58 A | 13.95 A | 2.7% |
| Impp | 13.31 A | 13.32 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.2 V | 0.0% |
| Vmpp | 43.22 V | 43.1 V | 0.3% |
| Isc | 13.58 A | 13.93 A | 2.6% |
| Impp | 13.31 A | 13.46 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52 V | 0.3% |
| Vmpp | 43.22 V | 43.07 V | 0.3% |
| Isc | 13.58 A | 13.52 A | 0.4% |
| Impp | 13.31 A | 13.24 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.36 V | 0.3% |
| Vmpp | 43.22 V | 43.43 V | 0.5% |
| Isc | 13.58 A | 13.61 A | 0.2% |
| Impp | 13.31 A | 13.36 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 51.99 V | 0.4% |
| Vmpp | 43.22 V | 42.99 V | 0.5% |
| Isc | 13.58 A | 13.89 A | 2.3% |
| Impp | 13.31 A | 13.26 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.31 V | 0.2% |
| Vmpp | 43.22 V | 43.35 V | 0.3% |
| Isc | 13.58 A | 14.01 A | 3.2% |
| Impp | 13.31 A | 13.38 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52 V | 0.3% |
| Vmpp | 43.22 V | 42.9 V | 0.7% |
| Isc | 13.58 A | 13.88 A | 2.2% |
| Impp | 13.31 A | 13.41 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.48 V | 0.6% |
| Vmpp | 43.22 V | 43.61 V | 0.9% |
| Isc | 13.58 A | 13.67 A | 0.7% |
| Impp | 13.31 A | 13.42 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.11 V | 0.1% |
| Vmpp | 43.22 V | 43.04 V | 0.4% |
| Isc | 13.58 A | 14.34 A | 5.6% |
| Impp | 13.31 A | 13.48 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.47 V | 0.6% |
| Vmpp | 43.22 V | 43.53 V | 0.7% |
| Isc | 13.58 A | 14.01 A | 3.2% |
| Impp | 13.31 A | 13.44 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.16 V | 0.0% |
| Vmpp | 43.22 V | 43.88 V | 1.5% |
| Isc | 13.58 A | 14.25 A | 4.9% |
| Impp | 13.31 A | 13.56 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.18 V | 52.42 V | 0.5% |
| Vmpp | 43.22 V | 43.3 V | 0.2% |
| Isc | 13.58 A | 14.38 A | 5.9% |
| Impp | 13.31 A | 13.52 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
Calculadora de compatibilidade da string
Verifique se a substituição funciona com o seu inversor
Procura de painéis
Todos os painéis compatíveis com um inversor
Já tem os painéis?
Encontre um inversor que se encaixe na sua instalação — gama MPPT e rácio DC/AC verificados.
Como funciona o algoritmo
Como os painéis são pontuados e emparelhados
Voc
52.18 V
Vmpp
43.22 V
Isc
13.58 A
Impp
13.31 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
575 W
Cells
144
Comprimento
2279 mm
Largura
1134 mm
Espessura
30 mm
Peso
32 kg
O Sunway SW575N-144 é um painel solar de 575 W. Encontrar um substituto compatível requer que as características elétricas — em particular Voc, Vmpp, Isc e coeficientes de temperatura — sejam correspondentes para garantir operação segura na mesma string.
Use o formulário acima para encontrar painéis com especificações compatíveis. Em seguida, verifique a substituição na Calculadora de Compatibilidade de Strings com seu inversor.
| Modelo | Potência | Voc | Isc |
|---|---|---|---|
| 565 W | 51.6 V | 13.47 A | |
| 570 W | 52 V | 13.52 A | |
| 580 W | 52.36 V | 13.61 A | |
| 585 W | 52.48 V | 13.67 A |
As especificações mais críticas são: número de células (exatamente 144), Voc próximo a 52.18 V (±5%) e coeficiente de temperatura TcVoc próximo a -0.25%/°C. Se o Voc diferir significativamente, a tensão da string em temperaturas extremas pode sair da faixa MPPT do inversor. O buscador de substituições pré-seleciona automaticamente os candidatos por esses critérios.
Um painel de maior potência geralmente tem um Vmpp ou Isc mais alto, o que pode afetar a tensão e a corrente da string. Pequenos aumentos (até 10–15%) são geralmente seguros se as outras especificações coincidirem. O buscador mostra uma pontuação de compatibilidade — 'Correspondência exata' significa especificações muito próximas. Sempre verifique a substituição na Calculadora de Compatibilidade de String com seu inversor antes da instalação.
Se o substituto tiver um Voc ou Vmpp significativamente diferente, a tensão da string pode sair da faixa MPPT do inversor, reduzindo a produção de energia ou causando falhas. Esse efeito é amplificado em temperaturas extremas. O buscador leva isso em conta automaticamente — ele pontua os candidatos pela proximidade das especificações elétricas com o Sunway SW575N-144 original.