610 W TOPCon Solarmodul mit 132 Zellen. Voc 49 V · Isc 15.96 A · TcVoc -0.24%/°C.
Wählen Sie das Modul, das ersetzt werden soll
155 Module gefunden · 3545 Module ausgeschlossen
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.1 V | 0.2% |
| Vmpp | 40.8 V | 40.82 V | 0.0% |
| Isc | 15.96 A | 16.06 A | 0.6% |
| Impp | 14.95 A | 15.19 A | 1.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 48.9 V | 0.2% |
| Vmpp | 40.8 V | 40.65 V | 0.4% |
| Isc | 15.96 A | 16 A | 0.3% |
| Impp | 14.95 A | 15.13 A | 1.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.02 V | 0.0% |
| Vmpp | 40.8 V | 40.72 V | 0.2% |
| Isc | 15.96 A | 16.1 A | 0.9% |
| Impp | 14.95 A | 15.23 A | 1.9% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.08 V | 0.2% |
| Vmpp | 40.8 V | 41.14 V | 0.8% |
| Isc | 15.96 A | 16.04 A | 0.5% |
| Impp | 14.95 A | 15.07 A | 0.8% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.1 V | 0.2% |
| Vmpp | 40.8 V | 40.82 V | 0.0% |
| Isc | 15.96 A | 16.06 A | 0.6% |
| Impp | 14.95 A | 15.19 A | 1.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.1 V | 0.2% |
| Vmpp | 40.8 V | 40.82 V | 0.0% |
| Isc | 15.96 A | 16.06 A | 0.6% |
| Impp | 14.95 A | 15.19 A | 1.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 48.9 V | 0.2% |
| Vmpp | 40.8 V | 40.65 V | 0.4% |
| Isc | 15.96 A | 16 A | 0.3% |
| Impp | 14.95 A | 15.13 A | 1.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 48.92 V | 0.2% |
| Vmpp | 40.8 V | 40.71 V | 0.2% |
| Isc | 15.96 A | 15.87 A | 0.6% |
| Impp | 14.95 A | 14.99 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.08 V | 0.2% |
| Vmpp | 40.8 V | 40.81 V | 0.0% |
| Isc | 15.96 A | 16.04 A | 0.5% |
| Impp | 14.95 A | 15.2 A | 1.7% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.08 V | 0.2% |
| Vmpp | 40.8 V | 40.74 V | 0.1% |
| Isc | 15.96 A | 16.08 A | 0.8% |
| Impp | 14.95 A | 15.22 A | 1.8% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.12 V | 0.2% |
| Vmpp | 40.8 V | 40.91 V | 0.3% |
| Isc | 15.96 A | 15.92 A | 0.3% |
| Impp | 14.95 A | 15.04 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49 V | 49.3 V | 0.6% |
| Vmpp | 40.8 V | 41.1 V | 0.7% |
| Isc | 15.96 A | 15.99 A | 0.2% |
| Impp | 14.95 A | 14.96 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
49 V
Vmpp
40.8 V
Isc
15.96 A
Impp
14.95 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
610 W
Cells
132
Bifaciality
80%
Länge
2383 mm
Breite
1133 mm
Rahmentiefe
30 mm
Gewicht
33.7 kg
Das AE Solar CMER-132BDS-610 ist ein 610 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 615 W | 49.3 V | 15.99 A | |
| 620 W | 49.6 V | 16.03 A | |
| 625 W | 49.9 V | 16.06 A | |
| 630 W | 50.2 V | 16.09 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 49 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.24%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original AE Solar CMER-132BDS-610 übereinstimmen.