650 W ABC Solarmodul mit 144 Zellen. Voc 54.9 V · Isc 15.27 A · TcVoc -0.22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
59 Module gefunden · 3641 Module ausgeschlossen
655 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 55 V | 0.2% |
| Vmpp | 44.79 V | 44.89 V | 0.2% |
| Isc | 15.27 A | 15.33 A | 0.4% |
| Impp | 14.52 A | 14.6 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 55.1 V | 0.4% |
| Vmpp | 44.79 V | 44.99 V | 0.4% |
| Isc | 15.27 A | 15.39 A | 0.8% |
| Impp | 14.52 A | 14.68 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.84 V | 0.1% |
| Vmpp | 44.79 V | 45.24 V | 1.0% |
| Isc | 15.27 A | 15.33 A | 0.4% |
| Impp | 14.52 A | 14.7 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.61 V | 0.5% |
| Vmpp | 44.79 V | 45.12 V | 0.7% |
| Isc | 15.27 A | 15.28 A | 0.1% |
| Impp | 14.52 A | 14.63 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 55.1 V | 0.4% |
| Vmpp | 44.79 V | 45.51 V | 1.6% |
| Isc | 15.27 A | 15.28 A | 0.1% |
| Impp | 14.52 A | 14.61 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
655 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.48 V | 0.8% |
| Vmpp | 44.79 V | 45.02 V | 0.5% |
| Isc | 15.27 A | 15.2 A | 0.5% |
| Impp | 14.52 A | 14.55 A | 0.2% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.2 V | 1.3% |
| Vmpp | 44.79 V | 45.5 V | 1.6% |
| Isc | 15.27 A | 15.18 A | 0.6% |
| Impp | 14.52 A | 14.51 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.26 V | 1.2% |
| Vmpp | 44.79 V | 45.32 V | 1.2% |
| Isc | 15.27 A | 15.51 A | 1.6% |
| Impp | 14.52 A | 14.79 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.16 V | 1.3% |
| Vmpp | 44.79 V | 45.22 V | 1.0% |
| Isc | 15.27 A | 15.45 A | 1.2% |
| Impp | 14.52 A | 14.71 A | 1.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.52 V | 0.7% |
| Vmpp | 44.79 V | 45.17 V | 0.8% |
| Isc | 15.27 A | 15.35 A | 0.5% |
| Impp | 14.52 A | 14.72 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.52 V | 0.7% |
| Vmpp | 44.79 V | 45.17 V | 0.8% |
| Isc | 15.27 A | 15.35 A | 0.5% |
| Impp | 14.52 A | 14.72 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.9 V | 54.42 V | 0.9% |
| Vmpp | 44.79 V | 45.07 V | 0.6% |
| Isc | 15.27 A | 15.3 A | 0.2% |
| Impp | 14.52 A | 14.65 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
54.9 V
Vmpp
44.79 V
Isc
15.27 A
Impp
14.52 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
650 W
Cells
144
Bifaciality
40%
Länge
2382 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32.2 kg
Das Aiko Solar AIKO-A650-MDE72Dw ist ein 650 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 655 W | 55 V | 15.33 A | |
| 660 W | 55.1 V | 15.39 A | |
| 665 W | 54.16 V | 15.45 A | |
| 670 W | 54.26 V | 15.51 A | |
| 675 W | 54.36 V | 15.57 A | |
| 680 W | 54.46 V | 15.63 A | |
| 685 W | 54.56 V | 15.69 A | |
| 690 W | 54.66 V | 15.75 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 54.9 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Aiko Solar AIKO-A650-MDE72Dw übereinstimmen.