450 W TOPCon Solarmodul mit 108 Zellen. Voc 39.98 V · Isc 14.25 A · TcVoc -0.26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
183 Module gefunden · 3517 Module ausgeschlossen
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.98 V | 0.0% |
| Vmpp | 33.24 V | 33.24 V | 0.0% |
| Isc | 14.25 A | 14.25 A | 0.0% |
| Impp | 13.54 A | 13.54 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.7 V | 0.7% |
| Vmpp | 33.24 V | 32.99 V | 0.8% |
| Isc | 14.25 A | 14.19 A | 0.4% |
| Impp | 13.54 A | 13.49 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 40.28 V | 0.8% |
| Vmpp | 33.24 V | 33.41 V | 0.5% |
| Isc | 14.25 A | 14.31 A | 0.4% |
| Impp | 13.54 A | 13.62 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.7 V | 0.7% |
| Vmpp | 33.24 V | 32.99 V | 0.8% |
| Isc | 14.25 A | 14.19 A | 0.4% |
| Impp | 13.54 A | 13.49 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 40.28 V | 0.8% |
| Vmpp | 33.24 V | 33.41 V | 0.5% |
| Isc | 14.25 A | 14.31 A | 0.4% |
| Impp | 13.54 A | 13.62 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.98 V | 0.0% |
| Vmpp | 33.24 V | 33.42 V | 0.5% |
| Isc | 14.25 A | 14.45 A | 1.4% |
| Impp | 13.54 A | 13.61 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.98 V | 0.0% |
| Vmpp | 33.24 V | 33.23 V | 0.0% |
| Isc | 14.25 A | 14.25 A | 0.0% |
| Impp | 13.54 A | 13.54 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.9 V | 0.2% |
| Vmpp | 33.24 V | 33.02 V | 0.7% |
| Isc | 14.25 A | 14.18 A | 0.5% |
| Impp | 13.54 A | 13.48 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.78 V | 0.5% |
| Vmpp | 33.24 V | 33.22 V | 0.1% |
| Isc | 14.25 A | 14.38 A | 0.9% |
| Impp | 13.54 A | 13.55 A | 0.1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 40 V | 0.1% |
| Vmpp | 33.24 V | 33.46 V | 0.7% |
| Isc | 14.25 A | 13.95 A | 2.1% |
| Impp | 13.54 A | 13.45 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 39.94 V | 0.1% |
| Vmpp | 33.24 V | 33.64 V | 1.2% |
| Isc | 14.25 A | 14.43 A | 1.3% |
| Impp | 13.54 A | 13.53 A | 0.1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.98 V | 40.01 V | 0.1% |
| Vmpp | 33.24 V | 33.05 V | 0.6% |
| Isc | 14.25 A | 14.69 A | 3.1% |
| Impp | 13.54 A | 13.93 A | 2.9% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
39.98 V
Vmpp
33.24 V
Isc
14.25 A
Impp
13.54 A
TcVoc
-0.26 %/°C
TcPmax
-0.31 %/°C
Pmax
450 W
Cells
108
Bifaciality
80%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
25 kg
Das AXITEC AC-450TGBL/108BB ist ein 450 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 440 W | 39.42 V | 14.13 A | |
| 445 W | 39.7 V | 14.19 A | |
| 455 W | 40.28 V | 14.31 A | |
| 460 W | 40.56 V | 14.36 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 39.98 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original AXITEC AC-450TGBL/108BB übereinstimmen.