640 W TOPCon Solarmodul mit 132 Zellen. Voc 50,35 V · Isc 16,15 A · TcVoc -0,26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
144 Module gefunden · 3566 Module ausgeschlossen
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.11 V | 0,5% |
| Vmpp | 41.84 V | 41.65 V | 0,5% |
| Isc | 16.15 A | 16.1 A | 0,3% |
| Impp | 15.3 A | 15.25 A | 0,3% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.3 V | 0,1% |
| Vmpp | 41.84 V | 41.8 V | 0,1% |
| Isc | 16.15 A | 16.43 A | 1,7% |
| Impp | 15.3 A | 15.55 A | 1,6% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 49.87 V | 1,0% |
| Vmpp | 41.84 V | 41.45 V | 0,9% |
| Isc | 16.15 A | 16.05 A | 0,6% |
| Impp | 15.3 A | 15.2 A | 0,7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0,000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0,000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.28 V | 0,1% |
| Vmpp | 41.84 V | 41.58 V | 0,6% |
| Isc | 16.15 A | 16.44 A | 1,8% |
| Impp | 15.3 A | 15.64 A | 2,2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.28 V | 0,1% |
| Vmpp | 41.84 V | 41.57 V | 0,6% |
| Isc | 16.15 A | 16.44 A | 1,8% |
| Impp | 15.3 A | 15.64 A | 2,2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.28 V | 0,1% |
| Vmpp | 41.84 V | 41.57 V | 0,6% |
| Isc | 16.15 A | 16.44 A | 1,8% |
| Impp | 15.3 A | 15.64 A | 2,2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
655 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.47 V | 0,2% |
| Vmpp | 41.84 V | 41.7 V | 0,3% |
| Isc | 16.15 A | 16.5 A | 2,2% |
| Impp | 15.3 A | 15.71 A | 2,7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
655 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.47 V | 0,2% |
| Vmpp | 41.84 V | 41.7 V | 0,3% |
| Isc | 16.15 A | 16.5 A | 2,2% |
| Impp | 15.3 A | 15.71 A | 2,7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.2 V | 0,3% |
| Vmpp | 41.84 V | 42 V | 0,4% |
| Isc | 16.15 A | 16.09 A | 0,4% |
| Impp | 15.3 A | 15 A | 2,0% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0,020 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.35 V | 0,0% |
| Vmpp | 41.84 V | 41.84 V | 0,0% |
| Isc | 16.15 A | 16.15 A | 0,0% |
| Impp | 15.3 A | 15.29 A | 0,1% |
| TcVoc | -0.26 %/°C | -0.23 %/°C | ±0,030 %/°C |
| TcPmax | -0.31 %/°C | -0.28 %/°C | ±0,030 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 50.1 V | 0,5% |
| Vmpp | 41.84 V | 41.64 V | 0,5% |
| Isc | 16.15 A | 16.37 A | 1,4% |
| Impp | 15.3 A | 15.49 A | 1,2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0,020 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.35 V | 49.95 V | 0,8% |
| Vmpp | 41.84 V | 41.46 V | 0,9% |
| Isc | 16.15 A | 16.05 A | 0,6% |
| Impp | 15.3 A | 15.2 A | 0,7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0,010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
50,35 V
Vmpp
41,84 V
Isc
16,15 A
Impp
15,3 A
TcVoc
-0,26 %/°C
TcPmax
-0,31 %/°C
Pmax
640 W
Cells
132
Bifaciality
80%
Länge
2382 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32,5 kg
Das AXITEC AC-640TGB/132WS ist ein 640 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| AC-625TGB/132TWS | 625 W | 49.63 V | 16 A |
| AC-630TGB/132WS | 630 W | 49.87 V | 16.05 A |
| AC-635TGB/132WS | 635 W | 50.11 V | 16.1 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 50,35 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original AXITEC AC-640TGB/132WS übereinstimmen.