735 W HJT Solarmodul mit 132 Zellen. Voc 50.54 V · Isc 18.37 A · TcVoc -0.24%/°C.
Wählen Sie das Modul, das ersetzt werden soll
94 Module gefunden · 3606 Module ausgeschlossen
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.46 V | 0.2% |
| Vmpp | 42.22 V | 42.13 V | 0.2% |
| Isc | 18.37 A | 18.28 A | 0.5% |
| Impp | 17.41 A | 17.33 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
725 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.38 V | 0.3% |
| Vmpp | 42.22 V | 42.03 V | 0.5% |
| Isc | 18.37 A | 18.18 A | 1.0% |
| Impp | 17.41 A | 17.25 A | 0.9% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.4 V | 0.3% |
| Vmpp | 42.22 V | 42.48 V | 0.6% |
| Isc | 18.37 A | 18.18 A | 1.0% |
| Impp | 17.41 A | 16.95 A | 2.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
715 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.35 V | 0.4% |
| Vmpp | 42.22 V | 42.44 V | 0.5% |
| Isc | 18.37 A | 18.1 A | 1.5% |
| Impp | 17.41 A | 16.85 A | 3.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.3 V | 0.5% |
| Vmpp | 42.22 V | 41.94 V | 0.7% |
| Isc | 18.37 A | 18.08 A | 1.6% |
| Impp | 17.41 A | 17.17 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
740 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.47 V | 0.1% |
| Vmpp | 42.22 V | 42.32 V | 0.2% |
| Isc | 18.37 A | 18.56 A | 1.0% |
| Impp | 17.41 A | 17.5 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.42 V | 0.2% |
| Vmpp | 42.22 V | 42.35 V | 0.3% |
| Isc | 18.37 A | 18.33 A | 0.2% |
| Impp | 17.41 A | 17.24 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.4 V | 0.3% |
| Vmpp | 42.22 V | 42.26 V | 0.1% |
| Isc | 18.37 A | 18.47 A | 0.5% |
| Impp | 17.41 A | 17.41 A | 0.0% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
745 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.54 V | 0.0% |
| Vmpp | 42.22 V | 42.38 V | 0.4% |
| Isc | 18.37 A | 18.65 A | 1.5% |
| Impp | 17.41 A | 17.59 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.47 V | 0.1% |
| Vmpp | 42.22 V | 42.41 V | 0.5% |
| Isc | 18.37 A | 18.44 A | 0.4% |
| Impp | 17.41 A | 17.34 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
740 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.57 V | 0.1% |
| Vmpp | 42.22 V | 42.5 V | 0.7% |
| Isc | 18.37 A | 18.53 A | 0.9% |
| Impp | 17.41 A | 17.42 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.54 V | 50.33 V | 0.4% |
| Vmpp | 42.22 V | 42.2 V | 0.0% |
| Isc | 18.37 A | 18.38 A | 0.1% |
| Impp | 17.41 A | 17.32 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
50.54 V
Vmpp
42.22 V
Isc
18.37 A
Impp
17.41 A
TcVoc
-0.24 %/°C
TcPmax
-0.24 %/°C
Pmax
735 W
Cells
132
Bifaciality
80%
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
33 mm
Gewicht
36.6 kg
Das Bluesun Solar BSM735G12-66HNH ist ein 735 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 715 W | 50.22 V | 17.98 A | |
| 720 W | 50.3 V | 18.08 A | |
| 725 W | 50.38 V | 18.18 A | |
| 730 W | 50.46 V | 18.28 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 50.54 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.24%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Bluesun Solar BSM735G12-66HNH übereinstimmen.