485 W ABC Solarmodul mit 108 Zellen. Voc 41 V · Isc 14.84 A · TcVoc -0.22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
137 Module gefunden · 3563 Module ausgeschlossen
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 41.1 V | 0.2% |
| Vmpp | 34.6 V | 34.7 V | 0.3% |
| Isc | 14.84 A | 14.88 A | 0.3% |
| Impp | 14.02 A | 14.13 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
480 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.9 V | 0.2% |
| Vmpp | 34.6 V | 34.5 V | 0.3% |
| Isc | 14.84 A | 14.8 A | 0.3% |
| Impp | 14.02 A | 13.92 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.94 V | 0.1% |
| Vmpp | 34.6 V | 34.56 V | 0.1% |
| Isc | 14.84 A | 15.08 A | 1.6% |
| Impp | 14.02 A | 14.32 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.85 V | 0.4% |
| Vmpp | 34.6 V | 34.53 V | 0.2% |
| Isc | 14.84 A | 15.13 A | 2.0% |
| Impp | 14.02 A | 14.33 A | 2.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.81 V | 0.5% |
| Vmpp | 34.6 V | 34.41 V | 0.5% |
| Isc | 14.84 A | 15.01 A | 1.1% |
| Impp | 14.02 A | 14.24 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 41.02 V | 0.0% |
| Vmpp | 34.6 V | 34.04 V | 1.6% |
| Isc | 14.84 A | 15.1 A | 1.8% |
| Impp | 14.02 A | 14.4 A | 2.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 41.02 V | 0.0% |
| Vmpp | 34.6 V | 34.04 V | 1.6% |
| Isc | 14.84 A | 15.1 A | 1.8% |
| Impp | 14.02 A | 14.4 A | 2.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
465 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 41.12 V | 0.3% |
| Vmpp | 34.6 V | 34.68 V | 0.2% |
| Isc | 14.84 A | 14.29 A | 3.7% |
| Impp | 14.02 A | 13.41 A | 4.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.71 V | 0.7% |
| Vmpp | 34.6 V | 34.4 V | 0.6% |
| Isc | 14.84 A | 15.06 A | 1.5% |
| Impp | 14.02 A | 14.24 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
470 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 41.18 V | 0.4% |
| Vmpp | 34.6 V | 34.74 V | 0.4% |
| Isc | 14.84 A | 14.32 A | 3.5% |
| Impp | 14.02 A | 13.54 A | 3.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
485 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.89 V | 0.3% |
| Vmpp | 34.6 V | 33.94 V | 1.9% |
| Isc | 14.84 A | 15.03 A | 1.3% |
| Impp | 14.02 A | 14.3 A | 2.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
485 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41 V | 40.89 V | 0.3% |
| Vmpp | 34.6 V | 33.94 V | 1.9% |
| Isc | 14.84 A | 15.03 A | 1.3% |
| Impp | 14.02 A | 14.3 A | 2.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
41 V
Vmpp
34.6 V
Isc
14.84 A
Impp
14.02 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
485 W
Cells
108
Bifaciality
43%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24.2 kg
Das Heckert Solar ZEUS 3.0+ 108-485 ist ein 485 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 480 W | 40.9 V | 14.8 A | |
| 490 W | 41.1 V | 14.88 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 41 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Heckert Solar ZEUS 3.0+ 108-485 übereinstimmen.