410 W TOPCon Solarmodul mit 108 Zellen. Voc 37.85 V · Isc 13.95 A · TcVoc -0.26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
73 Module gefunden · 3627 Module ausgeschlossen
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.95 V | 0.3% |
| Vmpp | 31.37 V | 31.58 V | 0.7% |
| Isc | 13.95 A | 14.02 A | 0.5% |
| Impp | 13.07 A | 13.14 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.86 V | 0.0% |
| Vmpp | 31.37 V | 31.27 V | 0.3% |
| Isc | 13.95 A | 14.01 A | 0.4% |
| Impp | 13.07 A | 13.28 A | 1.6% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.92 V | 0.2% |
| Vmpp | 31.37 V | 31.32 V | 0.2% |
| Isc | 13.95 A | 13.99 A | 0.3% |
| Impp | 13.07 A | 13.26 A | 1.5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.92 V | 0.2% |
| Vmpp | 31.37 V | 31.32 V | 0.2% |
| Isc | 13.95 A | 13.99 A | 0.3% |
| Impp | 13.07 A | 13.25 A | 1.4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
410 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.73 V | 0.3% |
| Vmpp | 31.37 V | 31.13 V | 0.8% |
| Isc | 13.95 A | 13.94 A | 0.1% |
| Impp | 13.07 A | 13.17 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.08 V | 0.6% |
| Vmpp | 31.37 V | 31.79 V | 1.3% |
| Isc | 13.95 A | 14.09 A | 1.0% |
| Impp | 13.07 A | 13.21 A | 1.1% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
410 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 37.63 V | 0.6% |
| Vmpp | 31.37 V | 31.08 V | 0.9% |
| Isc | 13.95 A | 13.92 A | 0.2% |
| Impp | 13.07 A | 13.2 A | 1.0% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.09 V | 0.6% |
| Vmpp | 31.37 V | 31.46 V | 0.3% |
| Isc | 13.95 A | 14.09 A | 1.0% |
| Impp | 13.07 A | 13.36 A | 2.2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.09 V | 0.6% |
| Vmpp | 31.37 V | 31.46 V | 0.3% |
| Isc | 13.95 A | 14.09 A | 1.0% |
| Impp | 13.07 A | 13.36 A | 2.2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.15 V | 0.8% |
| Vmpp | 31.37 V | 31.51 V | 0.4% |
| Isc | 13.95 A | 14.07 A | 0.9% |
| Impp | 13.07 A | 13.34 A | 2.1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.11 V | 0.7% |
| Vmpp | 31.37 V | 31.51 V | 0.4% |
| Isc | 13.95 A | 14.07 A | 0.9% |
| Impp | 13.07 A | 13.33 A | 2.0% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.85 V | 38.23 V | 1.0% |
| Vmpp | 31.37 V | 32 V | 2.0% |
| Isc | 13.95 A | 14.16 A | 1.5% |
| Impp | 13.07 A | 13.28 A | 1.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
37.85 V
Vmpp
31.37 V
Isc
13.95 A
Impp
13.07 A
TcVoc
-0.26 %/°C
TcPmax
-0.3 %/°C
Pmax
410 W
Cells
108
Bifaciality
80%
Länge
1722 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
21.5 kg
Das JA Solar JAM54D41-410/GB ist ein 410 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 415 W | 37.95 V | 14.02 A | |
| 420 W | 38.08 V | 14.09 A | |
| 425 W | 38.23 V | 14.16 A | |
| 430 W | 38.32 V | 14.23 A | |
| 435 W | 38.48 V | 14.3 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 37.85 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original JA Solar JAM54D41-410/GB übereinstimmen.