445 W TOPCon Solarmodul mit 96 Zellen. Voc 35.5 V · Isc 15.99 A · TcVoc -0.24%/°C.
Wählen Sie das Modul, das ersetzt werden soll
197 Module gefunden · 3503 Module ausgeschlossen
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.55 V | 0.1% |
| Vmpp | 29.69 V | 29.93 V | 0.8% |
| Isc | 15.99 A | 15.92 A | 0.4% |
| Impp | 14.99 A | 14.87 A | 0.8% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.54 V | 0.1% |
| Vmpp | 29.69 V | 29.69 V | 0.0% |
| Isc | 15.99 A | 15.86 A | 0.8% |
| Impp | 14.99 A | 14.99 A | 0.0% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.5 V | 0.0% |
| Vmpp | 29.69 V | 29.8 V | 0.4% |
| Isc | 15.99 A | 16.03 A | 0.3% |
| Impp | 14.99 A | 15.11 A | 0.8% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.3 V | 0.6% |
| Vmpp | 29.69 V | 29.5 V | 0.6% |
| Isc | 15.99 A | 15.92 A | 0.4% |
| Impp | 14.99 A | 14.92 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.7 V | 0.6% |
| Vmpp | 29.69 V | 29.89 V | 0.7% |
| Isc | 15.99 A | 16.06 A | 0.4% |
| Impp | 14.99 A | 15.06 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.58 V | 0.2% |
| Vmpp | 29.69 V | 29.61 V | 0.3% |
| Isc | 15.99 A | 15.85 A | 0.9% |
| Impp | 14.99 A | 15.03 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.54 V | 0.1% |
| Vmpp | 29.69 V | 29.36 V | 1.1% |
| Isc | 15.99 A | 16.04 A | 0.3% |
| Impp | 14.99 A | 15.17 A | 1.2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.48 V | 0.1% |
| Vmpp | 29.69 V | 29.87 V | 0.6% |
| Isc | 15.99 A | 15.6 A | 2.4% |
| Impp | 14.99 A | 14.9 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.59 V | 0.3% |
| Vmpp | 29.69 V | 29.4 V | 1.0% |
| Isc | 15.99 A | 15.84 A | 0.9% |
| Impp | 14.99 A | 14.98 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.4 V | 0.3% |
| Vmpp | 29.69 V | 29.9 V | 0.7% |
| Isc | 15.99 A | 16.14 A | 0.9% |
| Impp | 14.99 A | 15.06 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.44 V | 0.2% |
| Vmpp | 29.69 V | 29.83 V | 0.5% |
| Isc | 15.99 A | 15.6 A | 2.4% |
| Impp | 14.99 A | 14.92 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.5 V | 35.51 V | 0.0% |
| Vmpp | 29.69 V | 30.15 V | 1.5% |
| Isc | 15.99 A | 16.06 A | 0.4% |
| Impp | 14.99 A | 15.26 A | 1.8% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
35.5 V
Vmpp
29.69 V
Isc
15.99 A
Impp
14.99 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
445 W
Cells
96
Bifaciality
80%
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
23.7 kg
Das Jetion Solar JT445SNt(B) ist ein 445 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 440 W | 35.3 V | 15.92 A | |
| 450 W | 35.7 V | 16.06 A | |
| 455 W | 35.85 V | 16.13 A | |
| 460 W | 36 V | 16.2 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 35.5 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.24%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Jetion Solar JT445SNt(B) übereinstimmen.