575 W TOPCon Solarmodul mit 144 Zellen. Voc 51.27 V · Isc 14.31 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
205 Module gefunden · 3495 Module ausgeschlossen
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.22 V | 0.1% |
| Vmpp | 42.44 V | 42.42 V | 0.0% |
| Isc | 14.31 A | 14.56 A | 1.7% |
| Impp | 13.55 A | 13.79 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.42 V | 0.3% |
| Vmpp | 42.44 V | 42.68 V | 0.6% |
| Isc | 14.31 A | 14.32 A | 0.1% |
| Impp | 13.55 A | 13.59 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.47 V | 0.4% |
| Vmpp | 42.44 V | 42.59 V | 0.4% |
| Isc | 14.31 A | 14.37 A | 0.4% |
| Impp | 13.55 A | 13.62 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.07 V | 0.4% |
| Vmpp | 42.44 V | 42.29 V | 0.4% |
| Isc | 14.31 A | 14.25 A | 0.4% |
| Impp | 13.55 A | 13.48 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.47 V | 0.4% |
| Vmpp | 42.44 V | 42.59 V | 0.4% |
| Isc | 14.31 A | 14.37 A | 0.4% |
| Impp | 13.55 A | 13.62 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.16 V | 0.2% |
| Vmpp | 42.44 V | 42.52 V | 0.2% |
| Isc | 14.31 A | 14.55 A | 1.7% |
| Impp | 13.55 A | 13.76 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.31 V | 0.1% |
| Vmpp | 42.44 V | 42.67 V | 0.5% |
| Isc | 14.31 A | 14.63 A | 2.2% |
| Impp | 13.55 A | 13.83 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.16 V | 0.2% |
| Vmpp | 42.44 V | 42.52 V | 0.2% |
| Isc | 14.31 A | 14.55 A | 1.7% |
| Impp | 13.55 A | 13.76 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.02 V | 0.5% |
| Vmpp | 42.44 V | 42.37 V | 0.2% |
| Isc | 14.31 A | 14.47 A | 1.1% |
| Impp | 13.55 A | 13.69 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.17 V | 0.2% |
| Vmpp | 42.44 V | 42.27 V | 0.4% |
| Isc | 14.31 A | 14.1 A | 1.5% |
| Impp | 13.55 A | 13.37 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.17 V | 0.2% |
| Vmpp | 42.44 V | 42.27 V | 0.4% |
| Isc | 14.31 A | 14.1 A | 1.5% |
| Impp | 13.55 A | 13.37 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.27 V | 51.18 V | 0.2% |
| Vmpp | 42.44 V | 42.45 V | 0.0% |
| Isc | 14.31 A | 13.92 A | 2.7% |
| Impp | 13.55 A | 13.43 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
51.27 V
Vmpp
42.44 V
Isc
14.31 A
Impp
13.55 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
575 W
Cells
144
Bifaciality
80%
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32 kg
Das JinkoSolar JKM575N-72HL4-BDV-F5C1 ist ein 575 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 570 W | 51.07 V | 14.25 A | |
| 580 W | 51.47 V | 14.37 A | |
| 585 W | 51.67 V | 14.43 A | |
| 590 W | 51.86 V | 14.49 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 51.27 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original JinkoSolar JKM575N-72HL4-BDV-F5C1 übereinstimmen.