510 W TOPCon Solarmodul mit 108 Zellen. Voc 40,57 V · Isc 16,01 A · TcVoc -0,25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
175 Module gefunden · 3535 Module ausgeschlossen
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.43 V | 0,3% |
| Vmpp | 33.73 V | 33.71 V | 0,1% |
| Isc | 16.01 A | 15.98 A | 0,2% |
| Impp | 15.12 A | 15.13 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
515 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.63 V | 0,1% |
| Vmpp | 33.73 V | 33.91 V | 0,5% |
| Isc | 16.01 A | 16.03 A | 0,1% |
| Impp | 15.12 A | 15.19 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
515 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.62 V | 0,1% |
| Vmpp | 33.73 V | 33.64 V | 0,3% |
| Isc | 16.01 A | 16.08 A | 0,4% |
| Impp | 15.12 A | 15.31 A | 1,3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.68 V | 0,3% |
| Vmpp | 33.73 V | 33.6 V | 0,4% |
| Isc | 16.01 A | 16.06 A | 0,3% |
| Impp | 15.12 A | 15.19 A | 0,5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.48 V | 0,2% |
| Vmpp | 33.73 V | 33.44 V | 0,9% |
| Isc | 16.01 A | 15.97 A | 0,2% |
| Impp | 15.12 A | 15.11 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.6 V | 0,1% |
| Vmpp | 33.73 V | 33.7 V | 0,1% |
| Isc | 16.01 A | 15.93 A | 0,5% |
| Impp | 15.12 A | 15.14 A | 0,1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0,010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.42 V | 0,4% |
| Vmpp | 33.73 V | 33.45 V | 0,8% |
| Isc | 16.01 A | 16.02 A | 0,1% |
| Impp | 15.12 A | 15.25 A | 0,9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.24 V | 0,8% |
| Vmpp | 33.73 V | 33.6 V | 0,4% |
| Isc | 16.01 A | 15.88 A | 0,8% |
| Impp | 15.12 A | 15.03 A | 0,6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0,000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.55 V | 0,0% |
| Vmpp | 33.73 V | 34.17 V | 1,3% |
| Isc | 16.01 A | 15.68 A | 2,1% |
| Impp | 15.12 A | 14.78 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.55 V | 0,0% |
| Vmpp | 33.73 V | 34.17 V | 1,3% |
| Isc | 16.01 A | 15.68 A | 2,1% |
| Impp | 15.12 A | 14.78 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.55 V | 0,0% |
| Vmpp | 33.73 V | 34.17 V | 1,3% |
| Isc | 16.01 A | 15.68 A | 2,1% |
| Impp | 15.12 A | 14.78 A | 2,2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.57 V | 40.49 V | 0,2% |
| Vmpp | 33.73 V | 34.13 V | 1,2% |
| Isc | 16.01 A | 15.73 A | 1,7% |
| Impp | 15.12 A | 14.8 A | 2,1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0,000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0,010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
40,57 V
Vmpp
33,73 V
Isc
16,01 A
Impp
15,12 A
TcVoc
-0,25 %/°C
TcPmax
-0,3 %/°C
Pmax
510 W
Cells
108
Bifaciality
80%
Länge
1961 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
27,7 kg
Das Leapton Energy LP182*210-M-54-NB-510W ist ein 510 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| LP182*210-M-54-NB-475W | 475 W | 38.82 V | 15.59 A |
| LP182*210-M-54-NB-500W | 500 W | 40.07 V | 15.9 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 40,57 V (±5%) und Temperaturkoeffizient TcVoc nahe -0,25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Leapton Energy LP182*210-M-54-NB-510W übereinstimmen.