690 W HIBC Solarmodul mit 144 Zellen. Voc 55.6 V · Isc 15.68 A · TcVoc -0.21%/°C.
Wählen Sie das Modul, das ersetzt werden soll
12 Module gefunden · 3688 Module ausgeschlossen
685 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 55.5 V | 0.2% |
| Vmpp | 46.01 V | 45.91 V | 0.2% |
| Isc | 15.68 A | 15.6 A | 0.5% |
| Impp | 15 A | 14.92 A | 0.5% |
| TcVoc | -0.21 %/°C | -0.21 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
680 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 55.4 V | 0.4% |
| Vmpp | 46.01 V | 45.81 V | 0.4% |
| Isc | 15.68 A | 15.52 A | 1.0% |
| Impp | 15 A | 14.84 A | 1.1% |
| TcVoc | -0.21 %/°C | -0.21 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
675 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 55.3 V | 0.5% |
| Vmpp | 46.01 V | 45.71 V | 0.7% |
| Isc | 15.68 A | 15.44 A | 1.5% |
| Impp | 15 A | 14.77 A | 1.5% |
| TcVoc | -0.21 %/°C | -0.21 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
670 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 55.2 V | 0.7% |
| Vmpp | 46.01 V | 45.61 V | 0.9% |
| Isc | 15.68 A | 15.36 A | 2.0% |
| Impp | 15 A | 14.69 A | 2.1% |
| TcVoc | -0.21 %/°C | -0.21 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
690 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.66 V | 1.7% |
| Vmpp | 46.01 V | 45.72 V | 0.6% |
| Isc | 15.68 A | 15.75 A | 0.4% |
| Impp | 15 A | 15.1 A | 0.7% |
| TcVoc | -0.21 %/°C | -0.22 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
685 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.56 V | 1.9% |
| Vmpp | 46.01 V | 45.62 V | 0.8% |
| Isc | 15.68 A | 15.69 A | 0.1% |
| Impp | 15 A | 15.02 A | 0.1% |
| TcVoc | -0.21 %/°C | -0.22 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
680 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.46 V | 2.1% |
| Vmpp | 46.01 V | 45.52 V | 1.1% |
| Isc | 15.68 A | 15.63 A | 0.3% |
| Impp | 15 A | 14.94 A | 0.4% |
| TcVoc | -0.21 %/°C | -0.22 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
675 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.36 V | 2.2% |
| Vmpp | 46.01 V | 45.42 V | 1.3% |
| Isc | 15.68 A | 15.57 A | 0.7% |
| Impp | 15 A | 14.87 A | 0.9% |
| TcVoc | -0.21 %/°C | -0.22 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.62 V | 1.8% |
| Vmpp | 46.01 V | 45.27 V | 1.6% |
| Isc | 15.68 A | 15.46 A | 1.4% |
| Impp | 15 A | 14.8 A | 1.3% |
| TcVoc | -0.21 %/°C | -0.2 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.62 V | 1.8% |
| Vmpp | 46.01 V | 45.27 V | 1.6% |
| Isc | 15.68 A | 15.46 A | 1.4% |
| Impp | 15 A | 14.8 A | 1.3% |
| TcVoc | -0.21 %/°C | -0.2 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.62 V | 1.8% |
| Vmpp | 46.01 V | 45.27 V | 1.6% |
| Isc | 15.68 A | 15.46 A | 1.4% |
| Impp | 15 A | 14.8 A | 1.3% |
| TcVoc | -0.21 %/°C | -0.2 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.6 V | 54.26 V | 2.4% |
| Vmpp | 46.01 V | 45.32 V | 1.5% |
| Isc | 15.68 A | 15.51 A | 1.1% |
| Impp | 15 A | 14.79 A | 1.4% |
| TcVoc | -0.21 %/°C | -0.22 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
55.6 V
Vmpp
46.01 V
Isc
15.68 A
Impp
15 A
TcVoc
-0.21 %/°C
TcPmax
-0.24 %/°C
Pmax
690 W
Cells
144
Bifaciality
60%
Länge
2382 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32.5 kg
Das LONGi LR7-72HJD-690M ist ein 690 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 665 W | 55.1 V | 15.28 A | |
| 670 W | 55.2 V | 15.36 A | |
| 675 W | 55.3 V | 15.44 A | |
| 680 W | 55.4 V | 15.52 A | |
| 685 W | 55.5 V | 15.6 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 55.6 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.21%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original LONGi LR7-72HJD-690M übereinstimmen.