715 W HJT Solarmodul mit 132 Zellen. Voc 51.19 V · Isc 17.49 A · TcVoc -0.26%/°C.
Wählen Sie das Modul, das ersetzt werden soll
71 Module gefunden · 3629 Module ausgeschlossen
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.99 V | 0.4% |
| Vmpp | 43.51 V | 43.34 V | 0.4% |
| Isc | 17.49 A | 17.44 A | 0.3% |
| Impp | 16.44 A | 16.39 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51.39 V | 0.4% |
| Vmpp | 43.51 V | 43.68 V | 0.4% |
| Isc | 17.49 A | 17.54 A | 0.3% |
| Impp | 16.44 A | 16.49 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51.19 V | 0.0% |
| Vmpp | 43.51 V | 43.51 V | 0.0% |
| Isc | 17.49 A | 17.49 A | 0.0% |
| Impp | 16.44 A | 16.44 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.79 V | 0.8% |
| Vmpp | 43.51 V | 43.17 V | 0.8% |
| Isc | 17.49 A | 17.38 A | 0.6% |
| Impp | 16.44 A | 16.34 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.99 V | 0.4% |
| Vmpp | 43.51 V | 43.34 V | 0.4% |
| Isc | 17.49 A | 17.44 A | 0.3% |
| Impp | 16.44 A | 16.39 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51.39 V | 0.4% |
| Vmpp | 43.51 V | 43.68 V | 0.4% |
| Isc | 17.49 A | 17.54 A | 0.3% |
| Impp | 16.44 A | 16.49 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.59 V | 1.2% |
| Vmpp | 43.51 V | 43 V | 1.2% |
| Isc | 17.49 A | 17.33 A | 0.9% |
| Impp | 16.44 A | 16.29 A | 0.9% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
725 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.98 V | 0.4% |
| Vmpp | 43.51 V | 43.66 V | 0.3% |
| Isc | 17.49 A | 17.64 A | 0.9% |
| Impp | 16.44 A | 16.61 A | 1.0% |
| TcVoc | -0.26 %/°C | -0.22 %/°C | ±0.040 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 50.99 V | 0.4% |
| Vmpp | 43.51 V | 43.81 V | 0.7% |
| Isc | 17.49 A | 17.66 A | 1.0% |
| Impp | 16.44 A | 16.67 A | 1.4% |
| TcVoc | -0.26 %/°C | -0.22 %/°C | ±0.040 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51.12 V | 0.1% |
| Vmpp | 43.51 V | 43.1 V | 0.9% |
| Isc | 17.49 A | 17.8 A | 1.8% |
| Impp | 16.44 A | 17 A | 3.4% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51 V | 0.4% |
| Vmpp | 43.51 V | 43.96 V | 1.0% |
| Isc | 17.49 A | 17.68 A | 1.1% |
| Impp | 16.44 A | 16.72 A | 1.7% |
| TcVoc | -0.26 %/°C | -0.22 %/°C | ±0.040 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.19 V | 51.59 V | 0.8% |
| Vmpp | 43.51 V | 43.85 V | 0.8% |
| Isc | 17.49 A | 17.6 A | 0.6% |
| Impp | 16.44 A | 16.54 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
51.19 V
Vmpp
43.51 V
Isc
17.49 A
Impp
16.44 A
TcVoc
-0.26 %/°C
TcPmax
-0.24 %/°C
Pmax
715 W
Cells
132
Bifaciality
88%
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
33 mm
Gewicht
38.5 kg
Das Luxor Solar LX-715M/210-132+ GG HJT SW ECOLINE ist ein 715 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 700 W | 50.59 V | 17.33 A | |
| 705 W | 50.79 V | 17.38 A | |
| 710 W | 50.99 V | 17.44 A | |
| 720 W | 51.39 V | 17.54 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 51.19 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.26%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Luxor Solar LX-715M/210-132+ GG HJT SW ECOLINE übereinstimmen.