475 W IBC Solarmodul mit 120 Zellen. Voc 44.47 V · Isc 13.2 A · TcVoc -0.236%/°C.
Wählen Sie das Modul, das ersetzt werden soll
12 Module gefunden · 3499 Module ausgeschlossen
470 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 44.44 V | 0.1% |
| Vmpp | 38.06 V | 37.9 V | 0.4% |
| Isc | 13.2 A | 13.18 A | 0.2% |
| Impp | 12.48 A | 12.4 A | 0.6% |
| TcVoc | -0.236 %/°C | -0.236 %/°C | ±0.000 %/°C |
| TcPmax | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
465 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 44.41 V | 0.1% |
| Vmpp | 38.06 V | 37.74 V | 0.8% |
| Isc | 13.2 A | 13.16 A | 0.3% |
| Impp | 12.48 A | 12.32 A | 1.3% |
| TcVoc | -0.236 %/°C | -0.236 %/°C | ±0.000 %/°C |
| TcPmax | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
495 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.86 V | 1.4% |
| Vmpp | 38.06 V | 37.04 V | 2.7% |
| Isc | 13.2 A | 14.43 A | 9.3% |
| Impp | 12.48 A | 13.36 A | 7.1% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
490 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.91 V | 1.3% |
| Vmpp | 38.06 V | 36.43 V | 4.3% |
| Isc | 13.2 A | 14.01 A | 6.1% |
| Impp | 12.48 A | 13.45 A | 7.8% |
| TcVoc | -0.236 %/°C | -0.25 %/°C | ±0.014 %/°C |
| TcPmax | -0.27 %/°C | -0.29 %/°C | ±0.020 %/°C |
490 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.91 V | 1.3% |
| Vmpp | 38.06 V | 36.43 V | 4.3% |
| Isc | 13.2 A | 14.01 A | 6.1% |
| Impp | 12.48 A | 13.45 A | 7.8% |
| TcVoc | -0.236 %/°C | -0.25 %/°C | ±0.014 %/°C |
| TcPmax | -0.27 %/°C | -0.29 %/°C | ±0.020 %/°C |
490 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.66 V | 1.8% |
| Vmpp | 38.06 V | 36.84 V | 3.2% |
| Isc | 13.2 A | 14.37 A | 8.9% |
| Impp | 12.48 A | 13.31 A | 6.7% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
480 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.26 V | 2.7% |
| Vmpp | 38.06 V | 36.44 V | 4.3% |
| Isc | 13.2 A | 14.22 A | 7.7% |
| Impp | 12.48 A | 13.17 A | 5.5% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
485 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.46 V | 2.3% |
| Vmpp | 38.06 V | 36.64 V | 3.7% |
| Isc | 13.2 A | 14.3 A | 8.3% |
| Impp | 12.48 A | 13.23 A | 6.0% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
485 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.76 V | 1.6% |
| Vmpp | 38.06 V | 36.25 V | 4.8% |
| Isc | 13.2 A | 13.93 A | 5.5% |
| Impp | 12.48 A | 13.38 A | 7.2% |
| TcVoc | -0.236 %/°C | -0.25 %/°C | ±0.014 %/°C |
| TcPmax | -0.27 %/°C | -0.29 %/°C | ±0.020 %/°C |
485 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.76 V | 1.6% |
| Vmpp | 38.06 V | 36.25 V | 4.8% |
| Isc | 13.2 A | 13.93 A | 5.5% |
| Impp | 12.48 A | 13.38 A | 7.2% |
| TcVoc | -0.236 %/°C | -0.25 %/°C | ±0.014 %/°C |
| TcPmax | -0.27 %/°C | -0.29 %/°C | ±0.020 %/°C |
490 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.35 V | 2.5% |
| Vmpp | 38.06 V | 36.17 V | 5.0% |
| Isc | 13.2 A | 14.31 A | 8.4% |
| Impp | 12.48 A | 13.55 A | 8.6% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
495 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 44.47 V | 43.53 V | 2.1% |
| Vmpp | 38.06 V | 36.32 V | 4.6% |
| Isc | 13.2 A | 14.4 A | 9.1% |
| Impp | 12.48 A | 13.63 A | 9.2% |
| TcVoc | -0.236 %/°C | -0.23 %/°C | ±0.006 %/°C |
| TcPmax | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
44.47 V
Vmpp
38.06 V
Isc
13.2 A
Impp
12.48 A
TcVoc
-0.236 %/°C
TcPmax
-0.27 %/°C
Pmax
475 W
Cells
120
Länge
1913 mm
Breite
1035 mm
Rahmentiefe
35 mm
Gewicht
21.1 kg
Das Maxeon SPR-MAX7-475 ist ein 475 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 465 W | 44.41 V | 13.16 A | |
| 470 W | 44.44 V | 13.18 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 120), Voc nahe 44.47 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.236%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Maxeon SPR-MAX7-475 übereinstimmen.