455 W TOPCon Solarmodul mit 96 Zellen. Voc 35.61 V · Isc 16.22 A · TcVoc -0.22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
72 Module gefunden · 3628 Module ausgeschlossen
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.4 V | 0.6% |
| Vmpp | 30.1 V | 29.9 V | 0.7% |
| Isc | 16.22 A | 16.14 A | 0.5% |
| Impp | 15.12 A | 15.06 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.82 V | 0.6% |
| Vmpp | 30.1 V | 30.31 V | 0.7% |
| Isc | 16.22 A | 16.3 A | 0.5% |
| Impp | 15.12 A | 15.18 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.19 V | 1.2% |
| Vmpp | 30.1 V | 29.7 V | 1.3% |
| Isc | 16.22 A | 16.06 A | 1.0% |
| Impp | 15.12 A | 14.99 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 36.03 V | 1.2% |
| Vmpp | 30.1 V | 30.52 V | 1.4% |
| Isc | 16.22 A | 16.38 A | 1.0% |
| Impp | 15.12 A | 15.23 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.5 V | 0.3% |
| Vmpp | 30.1 V | 30.22 V | 0.4% |
| Isc | 16.22 A | 16.16 A | 0.4% |
| Impp | 15.12 A | 15.06 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.24 %/°C | -0.28 %/°C | ±0.040 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.68 V | 0.2% |
| Vmpp | 30.1 V | 30.41 V | 1.0% |
| Isc | 16.22 A | 16.22 A | 0.0% |
| Impp | 15.12 A | 15.13 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.24 %/°C | -0.28 %/°C | ±0.040 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 34.98 V | 1.8% |
| Vmpp | 30.1 V | 29.5 V | 2.0% |
| Isc | 16.22 A | 15.98 A | 1.5% |
| Impp | 15.12 A | 14.92 A | 1.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 36.24 V | 1.8% |
| Vmpp | 30.1 V | 30.73 V | 2.1% |
| Isc | 16.22 A | 16.46 A | 1.5% |
| Impp | 15.12 A | 15.3 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.45 V | 0.4% |
| Vmpp | 30.1 V | 30.29 V | 0.6% |
| Isc | 16.22 A | 16.08 A | 0.9% |
| Impp | 15.12 A | 15.02 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.78 V | 0.5% |
| Vmpp | 30.1 V | 30.5 V | 1.3% |
| Isc | 16.22 A | 16.32 A | 0.6% |
| Impp | 15.12 A | 15.25 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.24 %/°C | -0.28 %/°C | ±0.040 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.81 V | 0.6% |
| Vmpp | 30.1 V | 30.01 V | 0.3% |
| Isc | 16.22 A | 15.62 A | 3.7% |
| Impp | 15.12 A | 14.66 A | 3.0% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.61 V | 35.3 V | 0.9% |
| Vmpp | 30.1 V | 30.02 V | 0.3% |
| Isc | 16.22 A | 16.08 A | 0.9% |
| Impp | 15.12 A | 14.99 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.24 %/°C | -0.28 %/°C | ±0.040 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
35.61 V
Vmpp
30.1 V
Isc
16.22 A
Impp
15.12 A
TcVoc
-0.22 %/°C
TcPmax
-0.24 %/°C
Pmax
455 W
Cells
96
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
27 kg
Das Maysun Solar MS455MTDG-48HR ist ein 455 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 435 W | 34.77 V | 15.9 A | |
| 440 W | 34.98 V | 15.98 A | |
| 445 W | 35.19 V | 16.06 A | |
| 450 W | 35.4 V | 16.14 A | |
| 460 W | 35.82 V | 16.3 A | |
| 465 W | 36.03 V | 16.38 A | |
| 470 W | 36.24 V | 16.46 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 35.61 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Maysun Solar MS455MTDG-48HR übereinstimmen.