460 W TOPCon Solarmodul mit 120 Zellen. Voc 41.94 V · Isc 14.02 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
28 Module gefunden · 3672 Module ausgeschlossen
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.13 V | 0.5% |
| Vmpp | 34.72 V | 34.94 V | 0.6% |
| Isc | 14.02 A | 14.08 A | 0.4% |
| Impp | 13.25 A | 13.31 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.32 V | 0.9% |
| Vmpp | 34.72 V | 35.15 V | 1.2% |
| Isc | 14.02 A | 14.14 A | 0.9% |
| Impp | 13.25 A | 13.37 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.51 V | 1.4% |
| Vmpp | 34.72 V | 35.37 V | 1.9% |
| Isc | 14.02 A | 14.2 A | 1.3% |
| Impp | 13.25 A | 13.43 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.62 V | 0.8% |
| Vmpp | 34.72 V | 34.6 V | 0.3% |
| Isc | 14.02 A | 14.06 A | 0.3% |
| Impp | 13.25 A | 13.44 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
465 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.62 V | 0.8% |
| Vmpp | 34.72 V | 34.6 V | 0.3% |
| Isc | 14.02 A | 14.06 A | 0.3% |
| Impp | 13.25 A | 13.44 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.75 V | 1.9% |
| Vmpp | 34.72 V | 35.19 V | 1.4% |
| Isc | 14.02 A | 14.04 A | 0.1% |
| Impp | 13.25 A | 13.5 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.52 V | 1.0% |
| Vmpp | 34.72 V | 34.48 V | 0.7% |
| Isc | 14.02 A | 13.96 A | 0.4% |
| Impp | 13.25 A | 13.34 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
460 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.52 V | 1.0% |
| Vmpp | 34.72 V | 34.48 V | 0.7% |
| Isc | 14.02 A | 13.96 A | 0.4% |
| Impp | 13.25 A | 13.34 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
480 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.7 V | 1.8% |
| Vmpp | 34.72 V | 35.58 V | 2.5% |
| Isc | 14.02 A | 14.26 A | 1.7% |
| Impp | 13.25 A | 13.49 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
480 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 42.9 V | 2.3% |
| Vmpp | 34.72 V | 35.32 V | 1.7% |
| Isc | 14.02 A | 14.12 A | 0.7% |
| Impp | 13.25 A | 13.59 A | 2.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.42 V | 1.2% |
| Vmpp | 34.72 V | 34.38 V | 1.0% |
| Isc | 14.02 A | 13.86 A | 1.1% |
| Impp | 13.25 A | 13.24 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.94 V | 41.42 V | 1.2% |
| Vmpp | 34.72 V | 34.38 V | 1.0% |
| Isc | 14.02 A | 13.86 A | 1.1% |
| Impp | 13.25 A | 13.24 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.34 %/°C | ±0.050 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
41.94 V
Vmpp
34.72 V
Isc
14.02 A
Impp
13.25 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
460 W
Cells
120
Bifaciality
80%
Länge
1909 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
27 kg
Das RECOM RCM-460-7DBNE ist ein 460 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 465 W | 42.13 V | 14.08 A | |
| 470 W | 42.32 V | 14.14 A | |
| 475 W | 42.51 V | 14.2 A | |
| 480 W | 42.7 V | 14.26 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 120), Voc nahe 41.94 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original RECOM RCM-460-7DBNE übereinstimmen.